E3 Series System Connections
Designation
Description
W4
ARCNET Term
W5
RS-485 AUX Terminal OPEN
W7, W8
Municipal Jumpers
W9
Ground Fault Detection IN
SW2-1
Switch
SW2-2
Switch
SW2-3
Switch
SW2-4
Switch
SW2-5
Switch
J1
ILI to PM-9/PM-9G
COMM Port
J2
Local ARCNET
J5
Local ARCNET
J4
ARCNET Repeater
Connector
NOTE 1: Must be IN when connected via ribbon cable from this ILI95-MB-E3 at J1 to a PM-9/PM-9G connector J1.
Requires the removal of the JMP-1 on the PM-9/PM-9G.
Must be OUT when a ribbon cable is not installed in J1 and the ground fault detection is being provided by an INI-
VG Series node that is being powered from a common PM-9/PM-9G.
NOTE 2: Connect J1 to PM-9/PM-9G J1 only when the PM-9/PM-9G is NOT powering an INI-VG Series
sub-assembly.
NOTE 3: Use ILI95-MB-E3 Auxiliary RS485 Port (TB3-1 COM A & TB3-2 COM B) to connect to LCD-E3 (E3
annunciator module), LCD-7100 (7100 Remote Annunciator Module), ASM-16 (Addressable Switch Module), ANU-
48 (LED Annunciator Driver Module), DACT-E3 (E3 Digital Communicator Transmitter).
NOTE 4: RPT-E3 (E3 Repeater Module) is required when this ILI95-MB-E3 is networked via ARCNET to an INI-
VGE, INI-VGC, INI-VGX, or another RPT-E3 equipped node. Not required for LOCAL ARCNET communication
within a single enclosure.(J2 or J5).
NOTE 5: For Style 4, use terminals B+ and B- only. For Style 6, use terminals B+ and B- and connect return wires to
A+ and A-. For Style 7, wire as for Style 6 and use Isolator Modules and or Isolator Detectors per recommendations
as required.
NOTE 6: NAC1 and NAC2 are rated as Special Application.
Table 3.3.1.1
NOTE: For additional information on the wiring requirements, refer to the ILI95-MB-E3 Installation
Instructions (P/N 9001-0017).
104
OPEN
= Normal Operation.
SHORT = If the ILI95-MB-E3 is located at the end of the ARCNET bus.
= OFF (Normal Operations)
SHORT = ON (RS-485 Termination)
= For Master Box or Releasing
= ENABLE
OUT
= DISABLE (See Note 1)
1 ON
= SLC 1 DISABLED
(OFF = SLC 1 ENABLED)
2 ON
= SLC 2 DISABLED
(OFF = SLC 2 ENABLED)
3 ON
= NAC 1 & 2 DISABLED
(OFF = NAC 1 & 2 ENABLED)
4 ON
= BUZZER DISABLED
(OFF = BUZZER ENABLED)
5 ON
= RS-232 115.2 K BAUD
(OFF = 9600 BAUD or defined by CAMWorks™)
Connects to PM-9/PM-9G J1 (See Note 1 & 2)
Connects to J5 of the next ILI-E3, ILI95-E3 Series or ANX sub-assembly
Connects to J2 from the previous ILI-E3, ILI95-E3 Series or ANX sub-assembly
Connects to J7 of the INI-VG J7 or J10 of the
RPT-E3. (See Note 4)
ILI95-MB-E3 Field Wiring Connections (Continued)
E3 Series Installation/Operation Manual — P/N 9000-0574:I 11/04/10
Intelligent Loop Interface XP95-Main Board Connections
Comments