Calibrate Camera - HIKVISION DS-PRI120 User Manual

Security radar
Hide thumbs Also See for DS-PRI120:
Table of Contents

Advertisement

- Check Prioritize Display of Latest Alarm, the screen switches to 4-window mode and the
new alarm video will cyclically overlay 4 windows.
- Click Prev Page or Next Page to view unread alarm messages.
- Click Configure to enter Storage Schedule page. For detailed configuration, see Set Storage
Schedule via Storage Server .
- Click Exit to exit the alarm window.
4. Optional: Click
Note
For more details, see User Manual of iVMS-4200 Client Software.

5.5 Calibrate Camera

Calibrate the linked camera to ensure the accuracy of camera tracking.
Before You Start
• You need to disarm the radar before the operation. Right-click on the radar detection area and
click Disarm to disarm the radar.
• You need to link the speed dome to the zone before calibration, and set the speed dome initial
position.
• The installation height of the linked speed dome should to be more than 3 m.
Steps
1. In the client software, click Control Panel → Radar .
2. Click ... → Master-slave Tracking Settings on the upper-right corner of the page.
3. Double click the radar in the device list on the left. The live view window of the camera will be
displayed under the radar field diagram.
Security Radar User Manual
to disable alarm triggered pop-up image.