  • Page 1 DS-PR1-60 Security Radar User Manual...
  • Page 2 MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS...
  • Page 3 DS-PR1-60 User Manual Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol Description Indicates a hazardous situation which, if not avoided, will or could result in Danger death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in...
  • Page 4: Table Of Contents

    DS-PR1-60 User Manual Contents Chapter 1 Access to Client Software/Web Client ..................7 Chapter 2 Activation ..........................8 4.1 Activate Device via Client Software ......................8 4.2 Activate via SADP ............................9 4.3 Activate Device via Web Browser ......................10 Chapter 3 Wired Network Settings ......................
  • Page 5 DS-PR1-60 User Manual 5.6 Pop-up Alarm Notification ........................41 Chapter 6 Calibrating via Radar Calibration Tool ..................44 6.1 Download and Registration ........................44 6.2 Add Device .............................. 44 6.3 One-Point Calibration ..........................45 6.4 Multi-Point Calibration ..........................46 Chapter 7 Set Record and Storage Settings ....................48 1.1 Set Storage Settings ..........................
  • Page 6 DS-PR1-60 User Manual Chapter 11 System Management ......................57 11.1 Set Time............................57 11.2 Manage User ..........................57 11.3 System Maintenance ........................58 11.4 View Device Information ........................ 58 11.5 Search Log ............................58 11.6 Enabling Remote Debugging ......................58 11.7...
  • Page 7: Chapter 1 Access To Client Software/Web Client

    DS-PR1-60 User Manual Chapter 1 Access to Client Software/Web Client You can log in to the Client Software or the Web client to configure the device’s parameters. You can also configure the radar’s network parameters, alarm, permission, system, and search logs via the Web client.
  • Page 8: Chapter 2 Activation

    Before You Start • Get the iVMS-4200 client software from the supplied disk or the official Website at http:// www.hikvision.com/en/. Install the software by following the prompts. • The device and the PC running the software must be in the same subnet.
  • Page 9: Activate Via Sadp

    SADP is a tool to detect, activate, and modify the device’s IP address over the LAN. Before You Start • Get the SADP software from the supplied disk or the official Website http:// www.hikvision.com/en/, and install the SADP according to the prompts.
  • Page 10: Activate Device Via Web Browser

    DS-PR1-60 User Manual manually or checking Enable DHCP. 3) Input the admin password and click Modify to activate your IP address modification. 4.3 Activate Device via Web Browser Use a Web browser to activate the device. Use SADP software or PC client to search the online devices to get the IP address of the device, and activate the device on the Web page.
  • Page 11: Chapter 3 Wired Network Settings

    DS-PR1-60 User Manual Chapter 3 Wired Network Settings You can set the device IP address and other network parameters. Functions varied depending on the model of the device. 1. In the client software, enter Device Management page. 2. Select the device in the Device for Management list, click 3.
  • Page 12: Chapter 4 Radar Settings

    DS-PR1-60 User Manual Chapter 4 Radar Settings You can add zones and set camera tracking parameters for the radar in the client software or a Web client. 4.1 Radar Settings in the Web Client Edit maps, radars, zones, and trigger lines in a Web client.
  • Page 13: Add Zones

    DS-PR1-60 User Manual Figure 4-1 Edit Scale The word range is the predicted distance range of system. You should enter the number in the this range. 9. Click OK. 10. Adjust the radar position. Drag the sector to make the radar detection area cover the required filed. You can rotate the sector with the icon on the arc side of the sector.
  • Page 14 DS-PR1-60 User Manual • Early Warning Zone: The early warning zone will identify target that has potential risks in advance and trigger an alarm, but will not store the alarm track. The early warning zone is green. • Warning Zone: The warning zone will identify the targets entering the area and trigger the alarm. The warning zone is orange.
  • Page 15: Add Trigger Line

    DS-PR1-60 User Manual Figure 4-6 Move the Zone 4) Hold to move the zone. 5) Click outside the zone to exit the zone editing mode. To delete a zone, click in the zone editing mode. To edit the zone name and the zone type, click in the zone editing mode.
  • Page 16 DS-PR1-60 User Manual 5) Up to 4 trigger lines can be drawn. 6) Up to 1 dual-trigger line can be drawn. 7) Trigger line rule: A single arrow -> indicates that the target triggers an alarm when it crosses the trigger line in the direction of the arrow;...
  • Page 17: Radar Settings In The Client Software

    DS-PR1-60 User Manual • Delete: Click to delete the trigger line. 4.2 Radar Settings in the Client Software Edit radar parameters in client software. 4.2.1 Add Map 1. Click E-map to enter the radar page. 2. Select the radar group, and click Add map to load a map.
  • Page 18: Add The Radar To The Map

    DS-PR1-60 User Manual Figure 4-12 Edit Scale 7. Click OK. 4.2.2 Add the Radar to the Map After adding the map, you need to add a radar to the map. Before You Start Make sure that you have added the radar (when adding the device, check Import to Group) to the client software, as well as the map.
  • Page 19 DS-PR1-60 User Manual 4. Optional: Click to delete radar or click to edit radar parameters: Menu Description Hot Spot Name Radar name Hot Spot Color Color of radar name Hot Spot Icon The default icon cannot be changed Apply to Other Radar Hot Spots After checking, the changes will be synchronized to other radars.
  • Page 20 DS-PR1-60 User Manual Figure 4-15 Confirm Terminals 4) Click on the map to confirm the actual locations of marker 1 and marker 2. Figure 4-16 Confirm Actual Locations 5) Click OK on pop-up window. The system will automatically match the markers to the actual locations.
  • Page 21: Add Radar Zone

    DS-PR1-60 User Manual Figure 4-17 Finish Map Calibration 6) Click Radar Settings → End Map Calibration. 4.2.3 Add Radar Zone Before You Start You need to disarm the radar before the operation. Click Finish in the E-map page to exit the editing mode.
  • Page 22 DS-PR1-60 User Manual You can zoom in/out to adjust the size of the displayed radar area. Figure 4-19 Overlap Zones 4. Right-click to complete drawing, and the system will pop up a window. Enter the zone name, and select Early Warning Zone, Warning Zone, or Disabled Zone as the zone type.
  • Page 23 DS-PR1-60 User Manual Figure 4-20 Add a Marker Figure 4-21 Drag a Marker 3) Drag the marker to change the shape of the zone. Figure 4-22 Move the Zone 4) Hold to move the zone. 5) Click outside the zone to exit the zone editing mode.
  • Page 24: Add Trigger Line

    DS-PR1-60 User Manual 4.2.4 Add Trigger Line You can draw trigger lines for the radar detection area and set trigger line rule. Before You Start • The radar is added to the map. • Click Finish in the E-map page to exit the editing mode.
  • Page 25 DS-PR1-60 User Manual Figure 4-23 Draw a Trigger Line 4. Click OK to complete the drawing. 5. Optional: Click on the trigger line will appear different options: Edit, Delete and Move. You can edit the trigger line by clicking on it.
  • Page 26: Other Auxiliary Functions

    DS-PR1-60 User Manual Figure 4-27 Move the Trigger Line • Move the Trigger Line: Hold the editing area to move the trigger line. • Edit: Click to edit the trigger line name, trigger line rule and distance (only for Dual-trigger Line).
  • Page 27: Chapter 5 Camera Linkage Settings

    DS-PR1-60 User Manual Chapter 5 Camera Linkage Settings The radar can work with cameras such as speed domes and box cameras for target tracking and video recording. 5.1 Set Speed Dome Initial Position Set the initial position of the speed dome to ensure the tracking accuracy.
  • Page 28: Link The Camera To The Radar

    DS-PR1-60 User Manual Figure 5-2 Set Initial Position 5.2 Link the Camera to the Radar Before You Start Click Finish in the E-map page to exit the editing mode. Click on the radar icon and select Disarm to disarm the radar.
  • Page 29: Calibrate Camera

    DS-PR1-60 User Manual Figure 5-3 Add a Camera 3) Click OK. 3. Link zones and trigger lines to the camera. 1) Select a camera in the camera list. 2) Select zones and trigger lines in the Linkage Settings. 3) Click Save.
  • Page 30 DS-PR1-60 User Manual 1. In the client software, click Device Management → Group . 2. Select the group of the radar and click Ecoding Channels → Import . 3. Check cameras need to be calibrated and click Import. 4. Click E-map to enter the page and click Edit to enter the editing mode.
  • Page 31 DS-PR1-60 User Manual Figure 5-4 Calibration Page 9. Select a schedule for calibration point selection. According to the relative installation position of the radar and the camera, it is necessary to select a schedule for the calibration point selection (One-Point Calibration or Multi-Point Calibration).
  • Page 32 DS-PR1-60 User Manual Figure 5-5 Installation Scene for One-Point Calibration UM DS-PR1-60 090920NA...
  • Page 33: One Point Calibration

    DS-PR1-60 User Manual Figure 5-6 Installation Scene for Multi-Point Calibration 10. Calibrate the camera. According to the selected schedule, calibrate the camera by one-point calibration or multi-point calibration method. 5.3.1 One Point Calibration Before You Start Arrange a staff person (Operation staff) to perform the calibration operation in the client software, and a staff person (calibration staff) to cooperate with the calibration.
  • Page 34 DS-PR1-60 User Manual Figure 5-7 Select the Track 3. Ask the calibration staff to move to the calibration point within 66 ft to 131 ft (20 m to 40 m) directly in front of the radar, and then stand at the calibration point.
  • Page 35 DS-PR1-60 User Manual Select the calibration point in the Information list, and you can click Delete to delete the calibration point. The track disappears if the calibration staff is standing in the place for more than 7s. If the calibration staff does not move to the calibration point when the track disappears, you need to ask the calibration staff to move again to produce a track, and click the track to continue the calibration.
  • Page 36: Multipoint Calibration

    DS-PR1-60 User Manual 5.3.2 Multipoint Calibration Before You Start Arrange a staff person (Operation staff) to perform the calibration operation in the client software, and a staff person (Calibration staff) to cooperate with the calibration. 1. In the calibration page, select Multipoint Calibration as the calibration mode.
  • Page 37 DS-PR1-60 User Manual Figure 5-10 Multipoint Calibration Radar Page Every time a calibration point is calibrated completely, the operation staff should not adjust the PTZ buttons in the live view window (Adjustment will change the PTZ position of the current calibration point, and results in an incorrect calibration). You can adjust the PTZ buttons when calibrating the calibration point.
  • Page 38: Set Park Function For Linked Camera

    DS-PR1-60 User Manual You can save the calibration information successfully if there are three calibration points, otherwise, you cannot save it. 5.4 Set Park Function for Linked Camera After enabling the radar park mode, the main radar will control the camera to return to the set watch point when no target appears within 10 s in the radar detection area.
  • Page 39 DS-PR1-60 User Manual Figure 5-11 Set Camera Parking Point 3. Select a linked camera in the drop-down list. 4. Use function buttons on the right to adjust the camera screen center position (cross icon position) to the watch point. You can click on the screen and the screen will automatically adjust to the clicked center.
  • Page 40: Link The Camera To The Zone

    DS-PR1-60 User Manual 5.5 Link the Camera to the Zone Before You Start • Add the zone to the radar. • Add the camera to the client software. 1. In the client software, click Event Management → Alarm Event to enter the page.
  • Page 41: Pop-Up Alarm Notification

    DS-PR1-60 User Manual 5.6 Pop-up Alarm Notification Before You Start • Link the camera to the zone. • Add the camera, the NVR and the radar to the client software. • You need to check Pop-up Window in the security control panel event page.
  • Page 42 DS-PR1-60 User Manual UM DS-PR1-60 090920NA...
  • Page 43 DS-PR1-60 User Manual 5. Optional: Click to disable alarm triggered pop-up image. For more details, see the iVMS-4200 Client Software User Manual. UM DS-PR1-60 090920NA...
  • Page 44: Chapter 6 Calibrating Via Radar Calibration Tool

    DS-PR1-60 User Manual Chapter 6 Calibrating via Radar Calibration Tool 6.1 Download and Registration Get Radar Calibration Tool and registration. Before You Start Download and install Radar Calibration Tool from the official Website. 1. Open Radar Calibration Tool. 2. Click Register.
  • Page 45: One-Point Calibration

    DS-PR1-60 User Manual 6.3 One-Point Calibration Before You Start • You need to disarm the radar before the operation. • You need to add the camera in the radar list before calibration, and set the speed dome initial position. • The installation height of the linked speed dome should to be more than 9 ft 10 in (3 m).
  • Page 46: Multi-Point Calibration

    DS-PR1-60 User Manual Figure 6-2 Add a Calibration 8. Click Save. 6.4 Multi-Point Calibration Enter a short description of your task here (optional). Before You Start • Enter the prerequisites here (optional). • Enter the context of your task here (optional).
  • Page 47 DS-PR1-60 User Manual Figure 6-3 Multipoint Distribution Instance It is required to set at least four calibration points (equally distributed) when using multi- point calibration. 5. According to the calibration points, ask the calibration staff to move to a calibration point, and refer to step 4 to step 7 in One-Point Calibration to calibrate the calibration point.
  • Page 48: Chapter 7 Set Record And Storage Settings

    DS-PR1-60 User Manual Chapter 7 Set Record and Storage Settings 1.1 Set Storage Settings You can use storage server or NVR to store videos. 1.1.1 Set Storage Schedule via Storage Server Before You Start • Make sure your computer has already installed the Storage Server that should be selected as the component when installing client.
  • Page 49: Set Storage Schedule Via Nvr

    DS-PR1-60 User Manual 9. Click Save. For detailed settings, please refer to User Manual of iVMS-4200 Client Software. 1.1.2 Set Storage Schedule via NVR 1. In the client software, click , or enter the IP address of radar in brower to enter the Web client.
  • Page 50: Chapter 8 Alarm Settings

    3. Select Protocol Type from the drop-down list, select Server Address Type from the drop-down list, enter the server address, port No., and the user name. The protocol type NAL2300 is the Hikvision private protocol. 4. Click Save. 8.2 Notification Push When an alarm is triggered, if you want the send the alarm notification to the client, alarm center, cloud or mobile client, you can set the notification push parameters.
  • Page 51: Set Zone

    DS-PR1-60 User Manual Figure 8-2 Notification Push 2. Enable the target notification. • Alarm Event Notification: The device will push notifications when the zone alarm is triggered or restored. • System Status Notification: The device will push notifications when any status in the system is changed.
  • Page 52: Set Arming/Disarming Schedule

    DS-PR1-60 User Manual Figure 8-4 Relay You can click E-map → Edit → Radar Settings → Alarm Output to open or close the relay. 2. Select an relay, and click to enter the page. 3. Edit the relay name, and output time.
  • Page 53: Set Motion Speed

    DS-PR1-60 User Manual 2. Drag the mouse to draw the period bar on the time table, or click the period bar and enter the start and end time. You can set 2 arming/disarming periods each day. 3. Click OK to save.
  • Page 54: Chapter 9 Set Radar Advanced Function

    DS-PR1-60 User Manual Chapter 9 Set Radar Advanced Function 9.1 Set Master-Slave Tracking Settings If the radar needs multiple-radar linkage, you can arrange multiple radars for linkage detection and configure the radar master-slave relationship. Before You Start There are at least two online radars.
  • Page 55: Set Frequency Range Settings

    DS-PR1-60 User Manual 2. Select Open Mode, Shrub Mode, or Expert Mode as the radar sensitivity mode. • Open Mode: There are no large objects in the radar detection area. • Shrub Mode: There are shrubs and other objects that are likely to swing in the radar detection area.
  • Page 56: Chapter 10 View Alarm Information

    DS-PR1-60 User Manual Chapter 10 View Alarm Information The device supports alarm information query and alarm event playback. Before You Start Record and storage settings are required before searching and playing back alarm events. For details, see Set Record and Storage Settings.
  • Page 57: Chapter 11 System Management

    DS-PR1-60 User Manual Chapter 11 System Management 11.1 Set Time 1. Select the radar and click in the client software, or enter the radar IP address in the address bar of the Web browser. Click System → Time to enter the page.
  • Page 58: System Maintenance

    DS-PR1-60 User Manual 11.3 System Maintenance You can reboot the device, restore default settings, import/export configuration file, or upgrade the device remotely. Select the device and click in the client software, or enter the device IP address in the address bar of the web browser.
  • Page 59: Led Status

    DS-PR1-60 User Manual 11.7 LED Status You are able to enable LED function. Select the device and click in the client software, or enter the device IP address in the address bar of the web browser. Click System → Device Status to enter the page and you can enable or disable the LED function.
  • Page 60: Appendix A. Radar Mounting Height Recommendation

    DS-PR1-60 User Manual Appendix A. Radar Mounting Height Recommendation The recommended installation height is 6 ft 7 in to 9 ft 10 in (2 m to 3 m). The following table shows the detection range at different mounting heights. Figure A-1 Radar Mounting Height and Detection Range...
  • Page 61: Appendix B. Formatting Description

    DS-PR1-60 User Manual Appendix B. Formatting Description You can restore all parameters to default settings for formatting the security radar by the reset button. You can format the device as follows. 1. Power off the radar, and then hold the reset button while powering the radar on.
  • Page 62: Appendix C. Indicator Description

    DS-PR1-60 User Manual Appendix C. Indicator Description The indicator status description of the radar: Table C-1 Indicator Description Indicator Status Solid Green Radar powered on Solid Red Zone alarm occurred Flashing Red and Green Radar Network Disconnection/Radar Sensor Exception When formatting, flashes six times, indicating formatting was successful...
  • Page 63: Appendix D. Faq

    DS-PR1-60 User Manual Appendix D. FAQ D.1 How to Achieve an Optimum Detection Range? Answer: You can refer to Radar Mounting Height Recommendation for radar installation, and you should test the radar after installation to make sure it is properly mounted. The test method is as follows: You need to enable OSD function before testing.
  • Page 64: How To Raise The Camera Tracking Precision

    DS-PR1-60 User Manual D.4 How To Raise the Camera Tracking Precision? • Check if the speed dome initial position is set. If not, set the speed dome initial position. • Check if the calibration points are correct. Pay attention to the situation that the target is intercepted when calibrating.
  • Page 65: What Is The Reason That Failed To Draw A Zone Automatically

    DS-PR1-60 User Manual Figure D-2 Motion 2. Adjust the cursor to Next Page in the sport mode menu and click , then adjust the cursor to Max Ele Angle (DEG) and click to enter the page. Figure D-3 Maximum Elevation Angle Adjustment 3.
  • Page 66: What Makes A Failed Arming

    DS-PR1-60 User Manual D.7 What Makes a Failed Arming? The following two conditions will make a failed arming: • In the Radar page, if there is a moving target in the warning zone when you click → Arm to arm radars, it is impossible to enable mandatory arming, resulting in failed arming.
  • Page 67: Appendix E. Communication Matrix And Device Command

    Figure E-1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands. Note that the command list contains all commonly used serial ports commands for all Hikvision security control devices. Figure E-2 Device Command User Privacy Statement •...
  • Page 68 DS-PR1-60 User Manual Table E-1 User Privacy Information Description Password The password for the radar device account, used to log in to the device. Used to encrypt radar device configuration information. Username The username for the radar device account, used to log in to the device.
  • Page 69 DS-PR1-60 User Manual UM DS-PR1-60 090920NA...
  • Page 70 DS-PR1-60 User Manual UM DS-PR1-60 090920NA...
  • Page 71 DS-PR1-60 User Manual UD13649B UM DS-PR1-60 090920NA...

Table of Contents