  • Page 1: Installation Instructions

    Zenith HydroTap Taps ® Installation Instructions HydroTap Classic HydroTap Elite HydroTap Arc/Cube Classic All-In-One Celsius All-In-One Celsius Arc/Cube Mixer Classic/Arc/Cube 803341NZ - HydroTap Taps Install Instructions 09.18 v2.11 Page 1 of 24...
  • Page 2 Notes Page 2 of 24 803341NZ - HydroTap Taps Install Instructions 09.18 v2.11...
  • Page 3: Table Of Contents

    Contents 1 - HydroTap Classic & Elite ..........6 2 - HydroTap Arc / Cube ............8 3 - Mixer Tap ..............12 4 - Classic All-In-One Tap ..........14 5 - Celsius All-In-One Tap ..........18 6 - Celsius Arc / Cube ............21 803341NZ - HydroTap Taps Install Instructions 09.18 v2.11...
  • Page 4 Tap Options A range of HydroTap taps are offered to suit the customer’s needs. HydroTap Classic, Elite, HydroTap Arc and HydroTap Cube are standalone taps compatible with the HydroTap undersink unit, offering instant boiling, chilled and/or sparkling water. Classic, Arc and Cube Mixer Tap range may be used in conjunction with the standalone taps above to provide mixed hot and cold water.
  • Page 5: Special Tools Required

    35mm/50mm diameter hole saw for timber bench tops (not supplied) • 42mm AF tube spanner or wrench (not supplied) for fixing tap assembly (Celsius Arc/Cube) • Benchtop/Sinktop hole Recommended dispensing diameter required distance HydroTap Classic 35 mm 116 mm Elite 35 mm 116 mm HydroTap Arc/Cube 35 mm...
  • Page 6: Hydrotap Classic & Elite

    1 - HydroTap Classic & Elite HydroTap Classic Elite Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Alternatively, the tap could be mounted away from the sink using a font, available as an accessory.
  • Page 7 Installation Instructions - HydroTap Classic & Elite Typical HydroTap Installation Note: All silicon tubes must be cut to size. They must have a constant fall back to the unit. CHILLED MAINS MIXER MIXER BOILING BYPASS VENT BYPASS OUTLET Note: - Mains hose length...
  • Page 8: Hydrotap Arc/Cube

    2 - HydroTap Arc/Cube The HydroTap Arc/Cube has a spout that may be fixed in one of 6 angular positions and fixed in one of two height positions. The spout is fixed and does not swivel. NOTE: The tube kit must be fitted after the HydroTap has been mounted on the benchtop or sink. Refer to the tube kit assembly instructions, supplied with the tap kit.
  • Page 9 Installation Instructions - HydroTap Arc / Cube Height adjustment (Fixed position options) 50mm Angular adjustment (Fixed position options) Left Hand Control Right Hand Control Position A should not be selected NOTE: To reduce the risk of scalding, with Boiling Water units. Mounting BENCH TOP O-RING...
  • Page 10 Installation Instructions - HydroTap Arc / Cube Tube kit assembly Type C Type A Type B Type D Type E Type F Chilled Sparkling Boiling Chilled Sparkling Chilled / Ambient S/S Tube Used with BCS only NOTE: The L/H & R/H positions of the three way silicon tube are...
  • Page 11 Installation Instructions - HydroTap Arc / Cube Working from inside the cupboard, follow the directions for the relevant installation: Boiling Kit: Fit the Type A tube assembly into the L/H or R/H side of the three way silicon tube. Fit the Type F tube into the other side of the three way silicon tube. Boiling Ambient Kit: Fit the Type A tube assembly into the L/H or R/H side of the three way silicon tube.
  • Page 12: Mixer Tap

    WASHER NOTE: For low pressure installations Replace the normal 804178-Aerator with an 805734-flow straightener in the spout of a vented Zenith mixer tap. BRAIDED HOSE x 3 White/No colour: External mains water supply Red band: Mixer OUT Blue band: Mixer IN...
  • Page 13 Installation Instructions - Mixer Tap Typical HydroTap 4-in-1 Installation HydroTap Mixer Note: All silicon Connections tubes must be cut to size. They must have a constant fall back to the unit. POWER CHILLED MAINS MIXER BOILING BYPASS VENT BYPASS MIXER OUTLET CORD (Red)
  • Page 14: Classic All-In-One Tap

    4 - Classic All-In-One Tap Classic All-In-One Tap Vented or Mains Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Double Bowl For A-I-O tap: Cut a 50mm hole in the bench / sink top. 50mm hole SINK TOP 50mm...
  • Page 15 Installation Instructions - Classic All-In-One Tap Insert Silicon Tubes through Clamp Block (viewed from underneath) Thread the USB cable and silicon tubes through the circular clamp block. Check the tube colour alignment with the diagram below. Clamp the assembly in position using the threaded fixing nut (see fig. 4.5). Vented Mains silicon tube positions...
  • Page 16 Installation Instructions - Classic All-In-One Tap Assembled Clamp Block Vented Mains CLAMP BLOCK O-RING Mains IN To Mixer From HWS Mains IN connection FIXING NUT From Mixer BLUE to Chiller RED to Boiling connection connection CLEAR RED to Boiling BLUE to Chiller to vent connection connection...
  • Page 17 Installation Instructions - Classic All-In-One Tap Typical All-In-One Mains Installation with Booster (optional) Booster Note: All silicon tubes must be cut to size. They must have a constant fall back to the unit. CHILLED MAINS MIXER BOILING BYPASS VENT BYPASS MIXER OUTLET Note:...
  • Page 18: Celsius All-In-One Tap

    5 - Celsius All-In-One Tap O-RING SEAL Celsius All-In-One Tap BLACK RUBBER SEAL STEEL WASHER BRASS NUT For Celsius A-I-O Tap 50mm hole Double Bowl USB PLUG HOT & COLD BRAIDED HOSES • Pass all the hoses, tubes and USB lead through the 50mm hole.
  • Page 19 Installation Instructions - Celsius All-In-One Tap Plumbing Connection BC MODEL 3 WAYS MULTI CHANNEL BOILING CHILLED OUTLET OUTLET 3 STAINLESS STEEL TUBES STEAM VENT BOTTOM END OF JG STRAIGHT 3-WAY TUBE CONNECTOR USB PLUG FROM CHILLED OUTLET BRAIDED HOSE FROM BOILING OUTLET AT UNDERSINK UNIT.
  • Page 20 Installation Instructions - Celsius All-In-One Tap Typical Celsius All-In-One Mains Installation with Booster (optional) Booster Note: All silicon tubes must be cut to size. They must have a constant fall back to the unit. CHILLED MAINS MIXER BOILING BYPASS VENT BYPASS MIXER OUTLET Note:...
  • Page 21: Celsius Arc / Cube

    6 - Celsius Arc / Cube Celsius Arc Celsius Cube Special Tools Required: In addition to normal tools, the following will be required: • 35mm diameter sheet metal hole punch for sink tops (not supplied) 35mm diameter hole saw for timber bench tops (not supplied) •...
  • Page 22: 803341Nz - Hydrotap Taps Install Instructions 09.18 V2.11

    Installation Instructions - Celsius Arc / Cube • Pass all the hoses, tubes and USB lead through the 35mm hole. • Ensure the black rubber seal is correctly positioned to give a water tight seal • Secure the rubber & brass washers and large brass nut from inside the cupboard space.
  • Page 23: 803341Nz - Hydrotap Taps Install Instructions 09.18 V2.11

    Installation Instructions - Celsius Arc / Cube Typical BHA Celsius Arc/Cube Installation MAINS BOILING BYPASS VENT BYPASS MIXER MIXER Note: All silicon tubes must be cut to size. They must have a constant fall back to the unit. Note: - Mains hose length is 750mm - Plug and cord length is 1800mm...
  • Page 24 Images in this booklet have been modified and may not be true representations of the finished goods. The terms “Zenith” and “HydroTap” are registered trade marks of Zenith Heaters Ltd. Products described in this publication are manufactured under one or more patents and further patent applications are pending.

Table of Contents