R
epair
[2] -2. Motor section
DISASSEMBLING
Fig. 2
1. Prefilter (a) is held with Housing rib (b).
Turn Prefilter (a) to make Tab (c) free from Housing rib (b).
Remove Prefilter (a).
(b)
(a)
(c)
2. Unscrew seven 3x16 Tapping screws (d) from Housing R (e).
Remove Stay (f).
Note: Blow dust out of Housing before assembling.
(c)
(d)
(e)
(f)
(a)
3. Disconnect Flag terminals (g).
Remove DC Motor (h).
(g)
P 3/ 7