Wire; Comp Fan High - Maytag Amana PTC A Series Service Instructions Manual

Package terminal, air conditioners & heat pumps
Table of Contents

Advertisement

SCHEMATICS
NOTES:
WARNING: DISCONNECT POWER BEFORE SERVICING. WIRING
1
TO UNIT MUST BE PROPERLY POLARIZED (FOR 265V) AND GROUNDED.
2
RIBBED WIRE MUST BE CONNECTED AS SHOWN
3
ON HEAT PUMP MODELS ONLY.
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
H
YL10
RD13
S
C
RIBBED
2

WIRE

1
GN
ELECTRIC
HEATER
FUSE
RD33
BK18
BR34
BR35
LINE 1
HEATER HEATER LINE 2
Y/
C R G W2
W1 B RS FD RC
ON
OFF
MASTER
SWITCH
NTE and NTP Standard Unit
C
F
OD
FAN/COMP
CAP
COMP
R
BR14
WH15
BK20
FAN
REV
MOTOR
VALVE
SOLENOID
VT12
RD17
BK16
BK19
COMP FAN HIGH FAN LOWR-VALVE
INDOOR
SWITCH
24 VAC
ID TUBE
24 VAC
OD TUBE
On / Off
OUTDOOR
Fan Cycle
SWITCH
REMOTE/STANDARD
THERMOSTAT
3
FLOODBACK
PROTECTOR
BK40
BK40
BK30
3
BK30
SWITCHOVER
CONTROL
CHASSIS
GN1
PANEL
63