PROPER INSTALLATION
3. Lift the cabinet front off the chassis. Reverse this proce-
dure to reinstall the cabinet front.

CHASSIS INSTALLATION

1. Remove the cabinet front from the chassis as described in
Front Removal.
2. Insert the chassis into the wall sleeve.
Chassis
Slide Chassis In
3. Slide the chassis into the wall sleeve until the chassis
flanges contact the front edge of the wall sleeve.
Chassis
4. Secure the chassis to the wall sleeve using three screws
on each side of the chassis to ensure a proper seal be-
tween the chassis and the wall sleeve. The screws are
supplied in a plastic bag which is attached to the power
cord.
IMPORTANT NOTES:
1. The unit is equipped with a rubber grommet mounted com-
pressor. These grommets are factory set and require no
adjustment.
2. If a standard subbase is used, be sure the right hand sub-
base cover is removed before the chassis is installed in
the sleeve.
3. Check the indoor and outdoor grilles for obstructions to air
flow. The unit must be located where curtains, furniture,
trees, shrubs or other objects do not block the air flow to
and from the unit. If air is obstructed and/or deflected back
into the unit, the air conditioner's compressor may cycle
on and off rapidly. This could damage the compressor and
void the warranty.
Wall Sleeve
Outside
Wall
Wall Sleeve
Outside
Wall
Front Mounting Holes - Two mounting holes are provided to
give the owner the option of securing the front to the chassis.
The mounting holes are located behind the intake grille. The
owner must supply two 1/2 inch long #8 sheet metal screws
per unit. The two screws must be removed before the front can
be removed.
Mounting Screws
Location
Front Mounting Screws

WIRING

CAUTION
TO AVOID PROPERTY DAMAGE, PERSONAL INJURY
OR DEATH DUE TO ELECTRICAL SHOCK:
• DO NOT USE AN EXTENSION CORD WITH THIS UNIT.
• USE ONLY COPPER CONDUCTORS.
• WIRING TO THE UNIT MUST BE PROPERLY POLAR-
IZED AND GROUNDED.
Cord connection to a wall socket is not permitted for 265-volt
units. All 265-volt units must be hard wired using the hard wire
kit or make use of the plug-in receptacle in the standard sub-
base.
Heaterless Units
If a heaterless unit is ordered, field provisions must be made
for supplemental heat if desired. Refer to the Installation In-
structions supplied with the heater kit for a complete descrip-
tion of the installation procedures. All 208/230 volt heaterless
units are shipped with a 15 Amp power cord and all heaterless
265 volt units are shipped with a 20 Amp power cord.
When adding a heater kit to a unit, the power cord supplied
with the heater kit must be used in place of the power cord
supplied with the unit. The following table specifies power cord
rating requirements for the various heater kits.