Download Print this page

Camille Bauer KINAX 2W2 Operating Instructions

Programmable transmitter for angular position.

Advertisement

Quick Links

Safety precautions to be strictly observed are marked with following
symbols in the Operating Instructions:
The instruments must only be disposed of in the
correct way!
Contents
1. Read first and then ... ..........................................................................1
2. Brief description ....................................................................................1
3. Scope of supply ....................................................................................1
4. Specification and ordering information .................................................1
5. Technical data .......................................................................................2
6. Mounting and commissioning ...............................................................2
7. Dimensional drawings ...........................................................................3
8. Declaration of conformity ......................................................................4
1. Read first and then ...
The proper and safe operation of the device assumes that
the Operating Instructions are read carefully and the safety
warnings given in the various Section
6. Mounting and commissioning
are observed.
Unauthorized repair or alteration of the unit invalidates the warranty!
The device should only be handled by appropriate trained personnel who are
familiar with it and authorised to work in control technique installations.
2. Brief description
The KINAX 2W2 converts the angular position of a shaft into a load inde-
pendent direct current signal, proportional to the angular position. The unit
is contact free and has minimal mechanical abrasion on the input shaft. It
technically extends the delivery program of angular transmitters with a pro-
grammable version and thus creates a number of new technical application
possibilities.
Explosion-proof "Intrinsically safe EEx ia IIC T6" version with I.S. measuring
output rounds off this series of transmitters.
3. Scope of supply
Transmitter, one of the six versions (Fig. 1)
3 clamps (Fig. 2)
1 ea. Operating Instructions (Fig. 3) in English, French, German
1 Type Examination Certificate (Fig. 3), only for Ex version devices
KINAX 2W2 with
KINAX 2W2 with
standard drive shaft
special drive shaft
at front only,
at front only,
∅ 2 mm, length 6 mm.
∅ 6 mm, length 12 mm.
KINAX 2W2 with
KINAX 2W2 with
special drive shaft
special drive shaft
at front and at rear.
at front and at rear.
At front: ∅ 2 mm,
At front: ∅ 6 mm,
length 12 mm.
length 12 mm.
At rear: ∅ 2 mm,
At rear: ∅ 2 mm,
length 6 mm.
length 6 mm.
Fig. 1
Operating Instructions
Camille Bauer LTD
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Phone +41 56 618 21 11
Fax +41 56 618 35 35
e-mail: info@camillebauer.com
http://www.camillebauer.com
Fig. 2
4. Specification and ordering information
Significance of the digits 1. to 7.
Description
KINAX 2W2 with
special drive shaft
at front only,
∅ 1/4˝, length 12 mm.
KINAX 2W2 with
special drive shaft
at front and at rear.
At front: ∅ 1/4˝,
length 12 mm.
At rear: ∅ 2 mm,
length 6 mm.
Note: The remaining order code digits concern special features.
Fig. 3
1.
Version of the transmitter
Standard, measuring output non intrinsically safe
EEx ia IIC T6, ATEX
Measuring output intrinsically safe
2.
Mechanical angle range
Angle range, to 50
°
Angle range > 50 to 350
°
3.
Drive shaft
Standard, dia. 2 mm at front, length 6 mm
Special, dia. 2 mm at front, length 12 mm,
dia. 2 mm at rear, length 6 mm
Special, dia. 6 mm at front, length 12 mm
Special, dia. 6 mm at front, length 12 mm,
dia. 2 mm at rear, length 6 mm
Special, dia. 1/4˝ at front, length 12 mm
Special, dia. 1/4˝ at front, length 12 mm,
dia. 2 mm at rear, length 6 mm
4.
Output variable
Current, 4 to 20 mA, 2-wire connection
5.
Electrical connection
Connection to soldering terminals
Connection to screw terminals
6.
Test certificate
Without test certificate
Test certificate in German
Test certificate in English
7.
Configuration
Basic configuration, programmed
Programmed to order
Programmed to order, with zero position mark on
the drive shaft disk
Programmable
Transmitter for
angular position
KINAX 2W2
2W2 Be
149 973-01
07.06
Order Code
760-
1
2
1
2
1
2
3
4
5
6
1
1
2
0
D
E
0
1
2
1

Advertisement

loading

Summary of Contents for Camille Bauer KINAX 2W2

  • Page 1 Standard, measuring output non intrinsically safe 2. Brief description EEx ia IIC T6, ATEX The KINAX 2W2 converts the angular position of a shaft into a load inde- Measuring output intrinsically safe pendent direct current signal, proportional to the angular position. The unit Mechanical angle range is contact free and has minimal mechanical abrasion on the input shaft.
  • Page 2 After mounting, the transmitter can be moved to any position and configured Drive shafts dia. using the 2W2 software. A power supply connection to the KINAX 2W2 is not Sense required in order to use the 2W2 configuration software (Fig. 4; AUX switch 2 mm 6 mm resp.
  • Page 3: Dimensional Drawings

    Protection Class IP 00 acc. to IEC 529. 2. Place the measuring device in the zero position, i.e. in the position in which the KINAX 2W2 should output 4 mA. Adjust with the “ZERO” virtual knob until the output is correct.
  • Page 4: Declaration Of Conformity

    26.1 Typ / Type: KINAX 2W2 EX Fig. 12. KINAX 2W2 with special drive shaft at front and at rear. Das bezeichnete Produkt stimmt mit den Vorschriften folgender Europäischer Richtlinien überein, nachgewiesen durch die Einhaltung folgender Normen: At front: dia. 6 mm, length 12 mm. At rear: dia. 2 mm, length 6 mm.