Diagnostic Operations; To Start The Diagnostic Operation; Check Items - Casio 110CR Service Manual

Electronic
Table of Contents

Advertisement

8. DIAGNOSTIC OPERATIONS

8-1. To start the diagnostic operation

1. Make MAC operation.
2. Turn the mode switch to PGM position.
3. Input "99999999" and press "SUB TOTAL" key.
Note : Do not issue the receipt under REG / RF / X / Z mode before execute the diagnostic.
If the machine issued a receipt, the diagnostic does not start.
Print ing Layout
0 0 - 0 0 # 0 0 0 2
- d1d2d3d4 - - d5d6d7
d1d2d3d4 :
d5 :
d6 :
d7:

8-2. Check items

The following test can be checked in the test mode.
1. Key code check
2. Switch check
3. Individual function check
4. Country code write operation for EEPROM (PAD data)
0 0 - 0 0 - 0 0
Version No.
PAD condition
0 :
Japan
1 :
Export (ADD2)
2 :
US / Canada
3 :
Export (ADD3)
4 :
Export (ADD1)
0 :
Non taxable (Japan)
1 :
Taxable (Japan)
- :
Export version
0 :
118ER (Japan)
1 :
108ER (Japan)
- :
Export version
Receipt sample
0 0 - 0 0 - 0 0
0 0 - 0 0 # 0 0 0 2
- 2 8 6 2 - - 1 - -
- 11 -