Advertisement

Bosch
Connected Control
BCC50
Thermostat User Guide
BoschHeatingAndCooling.com
1

Advertisement

Table of Contents
loading

Summary of Contents for Bosch BCC50

  • Page 1 Bosch Connected Control BCC50 Thermostat User Guide BoschHeatingAndCooling.com...
  • Page 2: Table Of Contents

    Table of Contents Meet the Bosch Connected Control (BCC50 Thermostat) The Bosch Connected Control BCC50 Thermostat is compatible with the majority of 24VAC heating and cooling equipment to Device Settings Compatibility help you save energy and money. Easily control your home's temperature from the intuitive interface using the 5 back-lit touch...
  • Page 3: Compatibility

    Medium Philips screwdriver Millivolt systems User Guide (for attaching the Wall Plate to the wall) The Bosch Connected Control BCC50 Thermostat works Remote sensors Smartphone with most 24VAC systems, including gas, oil, propane, (for taking pictures of the existing wiring) electric, forced air, variable speed, heat pump and radiant.
  • Page 4: Thermostat Install

    If you see any of these images, within 5 minutes, air does not come out from the then insert the wall anchors unfortunately the BCC50 will not Y2 W2 G W R RC vents or the old thermostat does not even power provided into these work with your system.
  • Page 5 Location of the Mounting Screws Use the image you took with your smartphone of your old It is recommended to use the BCC50 Wall Plate as a thermostat wiring or the wire labels as a reference for reference guide to mark the mounting holes and ensure where to place each wire.
  • Page 6: Initial Setup

    Automatic Entry and Manual Entry. or Circuit Breaker box. policy, and press continue in the top right hand corner. Your BCC50 Thermostat is not yet configured to your If your thermostat is unable to connect to the app, follow The thermostat will power on Follow the on-screen instructions to create your account home’s HVAC system.
  • Page 7 Next. Click Next at the bottom of the screen to continue. Note: in a dual fuel system, the BCC50 will stage up from Image Area heat pump to fossil fuel following the stage settings, which If you have a Humidifier: can be modified in Advanced Settings >...
  • Page 8 Review your BCC50’s Initial Setup configuration and click Complete if you are happy with the setup. If you would like to change the week by clicking on the days you would like to copy that Date &...
  • Page 9: Advanced Settings

    In order to access the TITLE Default Description Advanced Settings of the BCC50 The fan’s lag time after the heating or cooling call is initiated when in Fossil Fuel, Heat Pump, or Fan Delay On Thermostat, your thermostat must be Cooling operation.
  • Page 10 Advanced Settings Installer Access To access the Installer Access, click Installer on the Advanced Settings screen and enter the Professional Access Code. Enter any one of the Action Codes in parenthesis below to gain access to that specific setting: Humidity Calibration (HC) Ability to adjust humidity readings to improve sensor accuracy as the thermostat nears the end of its lifecycle after years of use.
  • Page 11: Troubleshooting

    Advanced Settings Troubleshooting Device Log To access the Device Log, click Log on the Advanced Settings screen and enter the Professional Access Code. The Device Log stores up to 90 days’ worth of thermostat activity. To view historical data, select the time period you would like to view. Then select the function you would like to view: Need Functions...
  • Page 12: Wiring Diagrams

    Wiring Diagrams ---- Data ---- Data Single Stage Heat – Furnace Single Stage Heat – Boiler Ensure the system has a C-wire Ensure the system has a C-wire Ensure the pre-installed jumper wire remains between RH and RC Ensure the pre-installed jumper wire remains between RH and RC Connect the R, C, W1 and G wires from the Furnace to RH, C, W/E and G Connect the R, C and W1 wires from the boiler to RH, C and W/E terminals on the wall plate, respectively...
  • Page 13 Wiring Diagrams ---- Data Two Stage Heat Pump with ---- Data One Stage Emergency Heat Single Stage Heat Pump Ensure the system has a C-wire Ensure the system has a C-wire Ensure the pre-installed jumper wire remains between RH and RC Ensure the pre-installed jumper wire remains between RH and RC Connect the R, C, W1, Y1, Y2, O/B and G wires from the heat pump to RC, Connect the R, C, Y1, O/B and G wires from the heat pump to RC, C, Y, O/B and...
  • Page 14 Wiring Diagrams ---- Data Combined Single Stage Heat and Single Stage Cool Furnace and Air Conditioner Ensure the system has a C-wire Remove the pre-installed jumper wire from between RH and RC Connect the R, C, W1 and G wires from the Furnace to RH, C, W/E and G terminals on the wall plate, respectively Connect the R, C, Y1 and G wires from the Air Conditioner to RC, C, H/DH...
  • Page 15 User Manual How to use your BCC50 Thermostat Use the illuminated buttons to navigate the thermostat. If you do not see the illuminated buttons, simply click on a button’s location to illuminate all the lights. Note: the screen is not a touch screen. The buttons are the only way to interact with the device.
  • Page 16: Adjusting Temperature

    Adjusting Temperature Setpoint(s) Menu Overview No Schedule Schedule System From the Main Screen, use the up or down arrows to change Follow the same process as above to change the setpoint, but Use the up and down arrows to change the system mode of Use the up and down arrows to change the fan mode of your the temperature setpoint, and then press Ok to confirm your be aware that you are only changing the setpoint until the next...
  • Page 17 Menu Overview Menu Overview Accessory Wi-Fi Schedule Display Use the up and down arrows to change the relative humidity Use the up and down arrows to Connect, Re-Connect or Use the up and down arrows to change the active Schedule. Select Brightness to adjust the screen’s brightness setpoint, and then press Ok to confirm your selection.
  • Page 18 This is a perfect solution to help you achieve maximum comfort with minimum effort! Three Ways to Download The Connected Control App In the App Store or Google Play, search “Bosch Connected Control” Device Info Factory Reset or “BCC50” and then download the app.
  • Page 19 App Adjusting Temperature Setpoint(s) No Schedule Main Screen Overview From the Main Screen, tap Schedule Actual Room Temperature the current temperature Follow the same process as and use your finger to scroll Current Schedule Period above to change the up or down to change the setpoint, but be aware that Current Time temperature setpoint.
  • Page 20 App Menu Overview App Menu Overview Need Need Need Need Need Need Screen Screen Screen Screen Screen Screen Schedule Add a New Period Edit an Existing Period Delete an Existing Period Copy a Schedule Save Schedule To add a new Period to a To edit an existing Period, To delete an existing period, To copy a schedule to other...
  • Page 21: Mode

    Wi-Fi Device Messages Device Settings System Settings Similar to the BCC50 Thermostat, use To change the Wi-Fi Network that your thermostat uses to connect to the internet, Alert messages regarding your Follow the on-screen instructions to Follow the on-screen instructions to the Mode screens to adjust remotely the follow the on-screen instructions on your app.
  • Page 22 You must have a registered BCC50 account to set up and use your The setup process is now complete and you can start to control your BCC50 with your Alexa enabled device. Try out some of the commands above and enjoy!
  • Page 23 You must have a registered BCC50 account to set up and use your The setup process is now complete and you can start to control your BCC50 with your Alexa enabled device. Try out some of the commands above and enjoy!
  • Page 24: Wi-Fi

    Limited Warranty Bosch warrants that the Product will remain free from defects in material and workmanship for five (5) years from the date of original installation or from the date of manufacture if proof of installation is not available, provided it is properly installed and the other conditions of this warranty are met. If Bosch determines that the Product has a defect in workmanship or materials, Bosch, at its option, will repair or replace the defective part.
  • Page 25 Bosch Thermotechnology Corp. Watertown, MA • Londonderry, NH • Ft. Lauderdale, FL General Inquiries: 1-866-330-2725 www.boschheatingandcooling.com 70H995260B 1/19 Copyright © 2019 Bosch Thermotechnology Corp. All rights reserved. Subject to change without notice.
  • Page 26 FCC Caution This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 27 IC Caution: This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device. To maintain compliance with RF exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.