Bosch Programmable Thermostat
2H/2C/Hum Touch-Technology Thermostat
Installation, Operation & Application Manual

Advertisement

Table of Contents
loading

Summary of Contents for Bosch 8-733-944-325

  • Page 1 Bosch Programmable Thermostat 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual...
  • Page 2 2 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual 09.2016 | Bosch Thermotechnology Corp. Data subject to change...
  • Page 3: Table Of Contents

    Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 3 Table of Contents 1 Key to symbols and safety instructions 7 Factory preprogramming 1.1 Key to symbols 8 Troubleshooting 1.2 Safety 2 Thermostat specifi cations and features 2.1 Thermostat Controls 2.2 Thermostat features...
  • Page 4: Key To Symbols And Safety Instructions

    4 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual 1 Key to symbols and safety instructions 1.2 Safety Please read before proceeding 1.1 Key to symbols Warnings WARNING:  Always turn off power at the main power supply before installing, cleaning, or removing thermostat.
  • Page 5: Thermostat Specifi Cations And Features

    Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 5 2 Thermostat specifi cations and features 2.1 Thermostat Controls Up Arrow CALL Alarm Indicator SERVICE TECH Down Arrow Check Filter Indicator Left Arrow Right Arrow (Go Back) (Forward) Menu...
  • Page 6: Installation

    6 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual 3 Installation 3.3 Installing thermostat 3.1 Removing existing thermostat DANGER: ELECTRICAL SHOCK HAZARD  Turn off power at the main service panel by removing the fuse DANGER: ELECTRICAL SHOCK HAZARD or switching the appropriate circuit breaker to OFF position ...
  • Page 7: Wiring Diagram

    Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 7 4 Wiring diagram CO M Transformer 120 VAC 24 VAC Cool/Compressor #1 Heat #1/Reversing Valve Heat #2 Cool/Compressor #2 De(humidifier) Figure 2 Factory installed jumper between RH and RC is required.
  • Page 8: System Setup And Confi Guration

    8 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual 5 System setup and confi guration 5.4 Humidity output chart 5.1 Connection to the UPM (De)humidifi cation Setting With Humidity Control Demand The UPM’s ALARM COM terminal should be connected to R on the UPM board...
  • Page 9: Locking & Unlocking Thermostat

    Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 9 5.5 Locking & unlocking thermostat 5.8 Confi guration mode settings The setup screens for Confi guration Mode are as follows: MENU  Temperature Scale (F or C) LOCK ...
  • Page 10 1 0 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual Staged Off Outputs Heat Source: There are six heat source settings:   — Select whether the outputs for heating and cooling are staged off independently or are WARNING: satisfied simultaneously.
  • Page 11 Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 11 Auxiliary Delay ON (0-60 minutes) Minimum Cool Setpoint (45°F to 90°F) (7°C to 32°C)   — — Set the delay time in minutes for auxiliary heat to be locked out after a Adjust to control the minimum cool set temperature allowed.
  • Page 12 1 2 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual Room Temperature Offset (+9°F to -9°F) (+4.5°C to -4.5°C) Humidity Differential (1% to 10%)   — — Adjust to calibrate displayed room temperature to match actual room Set the percent diff...
  • Page 13 Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 13 Fan Delay Off Time (0, 30, 60, 90 seconds) Check Filter Timer (800-2500 hours)   — — Select the amount of time the fan continues to operate after the cool/ After the number of (fan running) hours specified, (for example, heat demand has been satisfied.
  • Page 14: Mode Of Operation

    1 4 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual 6 Mode of operation 6.1 Icon functions UP – Used to increase the time, set temperatures, and to adjust This thermostat is based on the i2020HR, but adds connections to the UPM to read confi...
  • Page 15: Operating Modes

    Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 15 6.2 Operating modes Cool Mode  The possible operating modes for the thermostat are: OFF, HEAT, EM HEAT, COOL, — In this mode, the thermostat controls the cooling system. When the and AUTO.
  • Page 16: Testing The Thermostat Humidity Control

    1 6 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual 6.3 Testing the thermostat 6.4 Testing the thermostat humidity control Humidifi cation Test – when set to humidifi cation, only Once the thermostat is confi gured, it should be thoroughly tested.
  • Page 17: Setting The Time And Date

    Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 17 6.5 Setting the time and date 6.6 Setting the program schedule Press , then press until CLOCK is displayed. The thermostat has four periods (WAKE, LEAVE, RETURN, SLEEP) that are customizable for each day of the week.
  • Page 18: View Screen Options

    1 8 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual 6.7 View screen options View if locked or unlocked — = Unlocked Press , then press repeatedly until the option displays — = Locked then press Press to advance to the next screen.
  • Page 19: Viewing Fault Codes

    Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 19 6.8 Viewing fault codes When one of the faults listed below causes a hard lockout on the UPM the unit compressors are disabled and the “Call Service Tech” light is illuminated.
  • Page 20: Schedule Override

    2 0 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual 6.9 Schedule override The schedule override feature allows the user to override the program schedule for 1 to 5 hours. In addition, if selected, the schedule can be overridden only until the next transition period.
  • Page 21: Factory Preprogramming

    Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 21 7 Factory preprogramming The thermostat comes pre-programmed with the following schedule: MONDAY thru SUNDAY WAKE 6:00 AM LEAVE 8:00 AM RETURN 6:00 PM SLEEP 10:00 PM HEAT 70°F HEAT 62°F...
  • Page 22: Troubleshooting

    2 2 | Bosch 2H/2C/Hum Touch-Technology Thermostat Installation, Operation & Application Manual 8 Troubleshooting Symptom Solution Check for 24 VAC at thermostat; display is blank when 24 VAC is not present. Time and day of week must be reset after No display power loss with no batteries installed.
  • Page 23 Installation, Operation & Application Manual Bosch 2H/2C/Hum Touch-Technology Thermostat | 23 NOTES: Bosch Thermotechnology Corp. | 09.2016 Data subject to change...
  • Page 24 United States and Canada Bosch Thermotechnology Corp. 50 Wentworth Avenue Londonderry, NH 03053 Tel: 866-305-9974 Fax: 603-965-7581 www.boschheatingandcooling.com BTC 469202102 A | 09.2016...

Table of Contents