Cabling And Mdf Connection; Connection Requirements; Cabling Precautions; Wiring Between The Chassis And The Mdf - NEC Univerge SV9100 System Hardware Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
S
7
C
ECTION
ABLING AND
7.1
7.2
7.3
SV9100 System Hardware Manual
MDF C
ONNECTION

Connection Requirements

The chassis is connected to each multiline terminal, single line telephone, optional
equipment, GCD-PVAA, DID/OPX, E&M Tie lines and digital trunks by a separate
twisted-pair cable through the Main Distribution Frame (MDF). The E&M Tie lines
are T1/FT1 lines and require multiple twisted pair cabling.

Cabling Precautions

When selecting cables and the MDF, future expansion or assignment changes
should be given due consideration. Avoid running cables in the following places:
A place exposed to the wind or rain.
A place near heat radiating equipment or where the PVC covering could be
affected by gases or chemicals.
An unstable place subject to vibration.

Wiring Between the Chassis and the MDF

7.3.1

Chassis Cables

The chassis is equipped with two MDF Cable Assemblies. NEC
recommends that the MDF Cable Assembly be used to connect the
multiline terminals, single line telephones (except PFT), PVAA and DID/
OPX lines. Refer to
4-40 MDF Cable Connections (Station) on page 4-100
Cable Connections (Trunk) on page
single line telephones with PFT, and other optional equipment with the
GCD-8DLCA/GCD-16DLCA, the connector and cabling must be locally
provided.

Figure 4-40 MDF Pin-Out (Connectors 1~6)

1
2
3
4
5
6
7
8
Figure 4-40 MDF Pin-Out (Connectors 1~6)
4-102. When installing E&M Tie lines,
1
2
3
4
5
6
7
8
and
Table
or
Table 4-41 MDF
4-99