Kenwood TKR-750 Programming Reference Manual page 55

Hide thumbs Also See for TKR-750:
Table of Contents

Advertisement

Function Name
Switch enable/disable the function assigned to the Auxiliary I/O port when the signal is applied to one of the PF
AUX I/O 1 On/Off
[AUX I/O 1 On/Off] to PF [AUX I/O 6 On/Off] ports.
-
You can assign the function when "Selectable" is configured to the Auxiliary I/O ports 1 to 6.
AUX I/O 6 On/Off
Assigning Functions to the Auxiliary Output Ports.)
Move the channel to one of CH 1 to CH 16 channels when the signal is applied to one of the PF [Channel 1] to
Channel 1
PF [Channel 16] ports.
-
You cannot configure this function when "Channel Select" is configured to Auxiliary I/O ports 1 to 4. "E2"
Channel 16
appears when specifying the channel without data.
Move to the next lower channel when the signal is applied to the PF [Channel Down] input port.
Channel Down
The channel without data is skipped.
Move to the next higher channel when the signal is applied to the PF [Channel Down] input port.
Channel Up
The channel without data is skipped.
Transmit CW ID when the signal is applied to the PF [CW ID On] input port.
CW ID On
This function is available on the channel having the CW ID.
CW Message 1
Transmits one of the CW Messages 1 to 8 when the signal is applied to one of the PF [CW Message 1] to PF
-
[CW Message 8] input ports.
CW Message 8
Switch the Saver Mode Off when the signal is applied to the PF [DC Power Save Off] input port.
DC Power Save Off
When the signal is detected with Down Edge, it cannot switch the DC Power Save function On after this
function is enabled.
Switch the Save Mode On when the signal is applied to the PF [DC Power Save On] input port.
DC Power Save On
When the signal is detected with Down Edge, it cannot switch the DC Power Save function Off after this
function is once enabled.
Switch the Save Mode On/Off when the signal is applied to the PF [DC Power Save On/Off] input port.
DC Power Save On/Off
6.4.3 Others Tab (Optional Features).)
All LEDs other than Power SW LED located on the front panel unlit when the signal is applied to the PF [Display
Display Off
Off] input port. This function is valid for only Power Saver Mode.
When the signal is detected with Down Edge, it cannot make all LEDs unlit after this function is enabled.
All LEDs on the front panel light when the signal is applied to the PF [Display On] input port. This function is
Display On
valid for only Power Saver Mode.
When the signal is detected with Down Edge, it cannot make all LEDs unlit after this function is enabled.
Switch the LEDs located on the front panel On/Off when the signal is applied to the PF [Display On/Off] input
Display On/Off
port. This function is valid for only Power Saver Mode.
Switch Repeat Hold Time Off when the signal is applied to the PF [Hold Time Disable] input port.
It can configure this function only when at least one channel is configured as the Repeat for Operation mode
Hold Time Disable
and Repeat Hold Time is enabled.
When the signal is detected with Down Edge, it cannot switch Hold Time On after this function is enabled.
Switch Repeat Hold Time On when the signal is applied to the PF [Hold Time Enable] input port.
It can configure this function only when at least one channel is configured as the Repeat for Operation mode
Hold Time Enable
and Repeat Hold Time is enabled.
When the signal is detected with Down Edge, it cannot switch Hold Time On after this function is enabled.
Switch disable/enable Repeat Hold Time when the signal is applied to the PF [Hold Time Disable/Enable] input
Hold Time Disable/
port. It can configure this function only when at least one channel is configured as the Repeat for Operation
Enable
mode and Repeat Hold Time is enabled.
It can disable the transmissions using the Local Mic PTT when the signal is applied to the PF [Local TX Disable]
Local TX Disable
input port. When the signal is detected with Down Edge, it cannot enable the transmission using the Local Mic
PTT after this function is enabled.
It can enable the transmission using the Local Mic PTT when the signal is applied to the PF [Local TX Enable]
Local TX Enable
input port. When the signal is detected with Down Edge, it cannot restrict the transmissions using the Local Mic
PTT after this function is enabled.
Switch disable/enable the transmissions using the Local Mic PTT when the signal is applied to the PF [Local TX
Local TX
Disable/Enable] input port. it can use this function only when the signal is detected with Down Edge.
Disable/Enable
" AUX Input Trigger (AUX Input).)
Switch the transmission power from Low to High when the signal is applied to the PF [Low Power Off] input
Low Power Off *1
port. This function activates only when at least one channel is configured as High Transmission Power.
to 6.2.11 TX High Power.)
Version: 1.01
Description
(Refer to 6.12 CW Message Window.)
(Refer to 6.4.1 Optional Features 1 Tab.)
(Refer to 6.4.1 Optional Features 1 Tab.)
(Refer to 6.4.1 Optional Features 1 Tab.)
Field Programming Reference (FPRG)
(Refer to 6.10.1 AUX Select Tab.)
(Refer to 6.3 CW ID Window.)
6 EDIT MENU
(Refer to Table 6-7
(Refer to
(Refer to
(Refer
50