RIDGID SeeSnake Compact M40 Operator's Manual

With truesense technology
Hide thumbs Also See for SeeSnake Compact M40:

Advertisement

Quick Links

WARNING!
Read this Operator's Man-
ual carefully before using
this tool. Failure to under-
stand and follow the con-
tents of this manual may
result in electrical shock,
fire, and/or serious per-
sonal injury.
Operator's Manual
For support and additional information
about using your Compact M40 go to
support.seesnake.com/compact-m40 or
scan this QR code.
Wit h
Technol ogy
Original Instructions – English – 1

Advertisement

Table of Contents
loading

Summary of Contents for RIDGID SeeSnake Compact M40

  • Page 1 Operator’s Manual Wit h Technol ogy WARNING! Read this Operator’s Man- ual carefully before using this tool. Failure to under- stand and follow the con- For support and additional information tents of this manual may about using your Compact M40 go to result in electrical shock, support.seesnake.com/compact-m40 or fire, and/or serious per-...
  • Page 2: Table Of Contents

    Table of Contents Introduction Regulatory Statements ............................... 3 Safety Symbols ................................3 General Safety Rules Work Area Safety ................................ 4 Electrical Safety ................................4 Personal Safety ................................4 Equipment Use and Care ............................5 Pre-Operation Inspection ............................5 Compact M40 Overview Description .................................
  • Page 3: Regulatory Statements

    Introduction Safety Symbols In this manual and on the product, safety symbols and The warnings, cautions, and instructions dis- signal words are used to communicate important safety cussed in this manual cannot cover all possi- information. This section is provided to improve under- ble conditions and situations that may occur.
  • Page 4: General Safety Rules

    General Safety Rules Personal Safety • Stay alert, watch what you are doing, and use com- WARNING mon sense when operating equipment. Do not use equipment while you are tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating equipment may result in serious injury.
  • Page 5: Equipment Use And Care

    Equipment Use and Care Pre-Operation Inspection • Do not force equipment. Use the correct equipment WARNING for your application. The correct equipment does the job better and more safely. • Do not use equipment if the power switch does not turn it on and off. Any equipment that cannot be controlled with the power switch is dangerous and must be repaired.
  • Page 6: Compact M40 Overview

    Compact M40 Overview Description TruSense Technology Description ™ The RIDGID SeeSnake Compact M40 camera reel of- ® ® fers fast, easy setup and can take on the most diverse TruSense technology establishes a two-way communi- and demanding inspection conditions.The Compact M40...
  • Page 7: Standard Equipment

    ‡ While the camera can function in extreme temperatures, some image quality changes may occur. Frequency 512 Hz Distance Measurement Type TruSense Counter Standard Equipment • SeeSnake Compact M40 Data Communication Two-Way • Docking System Push Cable • Operator’s Manual Length 40 m [131 ft] •...
  • Page 8: System Components

    Specific Safety Information System Components WARNING Frame Docking System This section contains important safety information that is specific to the Compact M40. Read these pre- cautions carefully before using the equipment to re- duce the risk of electrical shock, fire, and/or serious injury.
  • Page 9: Operating Instructions Placement

    Operating Instructions Inspection Overview To perform a pipe inspection, connect any See Snake Placement monitor to the reel, power on the system, push the push cable through the pipe, and observe the display. Set up your SeeSnake system near the pipe entrance so you can manipulate the push cable while viewing the For advanced inspection options, such as capturing monitor.
  • Page 10: Cs6X Versa Docking System

    CS6x Versa Docking System Removing the Monitor 1. Place the Compact M40 so you can grasp both WARNING quick-release knobs. Do not carry the Compact M40 by the monitor’s 2. Pull both knobs out and away from the docking fins. mounting frame or kickstand.
  • Page 11: System Cable Removal

    System Cable Removal System Cable Installation 1. Disconnect the system cable from the reporting To install the system cable, follow these steps: monitor and remove the monitor from the docking 1. Align the arrow on the slip-ring dial with the unlock system.
  • Page 12: Maintenance And Support Cleaning

    Maintaining Components Service and repair of the camera reel must be performed at a RIDGID Independent Authorized Service Center. To find your nearest service center or for any service or re- Camera Head pair questions: Scratches on the camera have a minimal effect on its •...
  • Page 13 Compact M40 – English – 13...
  • Page 14 14 – English – Compact M40...
  • Page 15 Compact M40 – English – 15...
  • Page 16 RIDGID and the RIDGID logo are trademarks of Ridge Tool Company, registered in the USA and other countries. All other registered and unregistered trademarks and logos mentioned herein are the property of their respective owners. Mention of third- party products is for informational purposes only and constitutes neither an endorsement nor a recommendation.

Table of Contents