Safety Cable Use

The supplied safety cable MUST always be used when rigging luminaires on bars, truss, etc. (as shown in Figure 4).
FOR LUMINAIRE, the supplied safety cable is recommended for all hanging installation and may be required by
national and local codes. Loop safety cable through luminaire yoke assembly as shown and attach to structure. FOR
LENS TUBE, attach a safety cable (sold separately) to lens tube anchor point and to yoke assembly. You should
always consult and follow all local and national codes and regulations for mounting and installation of luminaire.
WARNING! If your luminaire is equipment with the eyelet as indicated in Figure 4, DO NOT attach safety cable to
this eyelet on luminaire body. This eyelet feature was included for another purpose other than the safety cable and
will be removed from future production models.

6. Pan and Tilt Adjustments

Pan Adjustment

The pan adjustment of a PLPROFILE4 LED Luminaire is achieved by loosening the yoke bolt of the securing clamp
attached to the luminaire's yoke assembly. Loosen the bolt, set the luminaire to the desired position and retighten.

Tilt Adjustment

PLPROFILE4 LED Luminaires offer variable tilt settings. The unit can be set at a specific angle (in relation to its
mounting position) or at an angle between 0 to 90 degrees. When the yoke is in the position shown in Figure 4, you
have full range access to shutters the gate etc. If you flip the yoke over some access is reduced but the over all volume
the luminaire takes up is reduced. This is particularly useful in tightly hung lighting positions or in theatres with low
grids.
Safety Cable
(supplied with
luminaire)
Yoke Assembly
NOT a safety cable
attachment point.
To adjust and set tilt angle of the luminaire:
Step 1. Mount luminaire in desired location (see
Step 2. Loosen, but do not remove, T-Handle Tilt Locks at base of yoke assembly as shown in Figure 4.
Step 3. Position luminaire to desired tilt position.
Step 4. Retighten T-Handle Tilt Locks to set position.
1 2
INSTALLATION AND SET UP
SAFETY CABLE: FOR LUMINAIRE, the supplied safety cable is
recommended for all hanging installation and may be required by
national and local codes. Loop safety cable through luminaire yoke
assembly as shown and attach to structure. FOR LENS TUBE, attach a
safety cable (sold separately) to lens tube anchor point and to yoke
assembly.
Safety Cable
(sold separately)
Figure 4: Luminaire Tilt Adjustment
"Mounting" on page 11
PLPROFILE4 LED Luminaires
Cooling Vents (see note below)
NOTE: To allow for proper cooling, make
sure luminaire head is orientated as shown
(with cooling vents pointed upwards).
T-Handle Tilt Lock
(one on each side)
Sliding Yoke Assembly