PLPROFILE4 LED Luminaires

5. Mounting

WARNING! Before attempting any installation or service, disconnect all power at power source. Dimming the
luminaire does not disconnect power. Installation and service should only be performed by a trained and qualified
professional.

Using Supplied C-Clamp

As illustrated in Figure 3 on page 11, at yoke assembly, thread clamp mounting bolt (with washer installed) through
center clamp mounting hole at top of yoke, through Top Box Assembly, and thread bolt into C-Clamp. Securely
tighten bolt (by hand) into clamp (but do not overtighten).
Center Clamp Mounting Hole
Yoke Assembly
To mount on a telescopic stand, reverse the yoke under the luminaire and bolt to stand. Please note luminaire
orientation (see note in Figure 3).
Note: After installing Clamp and Top Box assembly, connect luminaire cable assembly to Top Box Assembly before
mounting luminaire. Please note that the cable connector is keyed.
Top Box Assembly
Figure 3: Luminaire Mounting
Installation & User's Manual
C-Clamp
Top Box Assembly
Flat Washer
C-Clamp Bolt
Luminaire Cooling Vents
NOTE: To allow for proper cooling, make sure
luminaire head is orientated as shown (with
cooling vents pointed upwards).
Luminaire Cable
Assembly
Mounting