Installation & User's Manual

3. Connecting Power

Note: Refer to Figure 1 on page 8 for AC Input and Output connections.
If the unit is supplied with an AC input cable, Table 2 describes how to connect power to your PLPROFILE4 LED
Luminaire . Field wiring of the PLPROFILE4 LED Luminaire is straight forward. A total of 3 wires/conductors need
to be brought to the unit. The following wiring scheme is required:
Table 2: PLPROFILE4 LED Luminaire AC Input Connections
Wire Color
Brown
Green/Yellow

4. Connecting to the DMX512 Network

Note: Refer to Figure 1 on page 8 for DMX512 Input and Output/Thru connections.
Basic DMX512 installation consists of connecting multiple PLPROFILE4 LED Luminaires together (up to 30
luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX
connector on the first PLPROFILE4 LED Luminaire. Another cable runs from the other DMX connector on the first
unit to a DMX connector on the next PLPROFILE4 LED Luminaire (or DMX512 device to be controlled).
Note: For more information on DMX512 networking and systems, refer to
page
1. For PLPROFILE4 LED Luminaire DMX Mapping, refer to
DMX512
(from console or
control device)
1 0
INSTALLATION AND SET UP
Main / Line (120 to 240VAC)
Blue
DMX512
Note: Remaining pins on each connector are not used.
Figure 2: Connecting DMX512
Purpose
Neutral
Ground
AC Input Connector
(on back of unit)
"DMX CONTROL" on page
(out from first
to second luminaire)
PLPROFILE4 LED Luminaires
DMX512 Connections
DMX512 Signal
XLR Pin
Common (Drain)
1
DMX512 -
2
DMX512 +
3
PLPROFILE4 LED Luminaires
Neutral
Ground / Earth
"Additional Resources for DMX512" on
25.
DMX512
(out to the next luminaire or
DMX512 controlled device)
Main /
Line

Advertisement