OTDR-FIBER-END-NOT-DETECTED-TX

OTDR-FIBER-END-NOT-DETECTED-TX
Default Severity: NA
Logical Object: EQUIPMENT
The OTDR-FIBER-END-NOT-DETECTED-TX alarm is raised when the OTDR module cannot return a
valid fiber end.
Clear the OTDR-FIBER-END-NOT-DETECTED-TX Alarm
Execute the Auto Scan.
Note
If the fiber is affected by high reflections or if the fiber is longer than 100 km, the fiber end cannot be found.
Hence, the alarm will not be cleared.
If the alarm does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-HYBRID-FAR-END-IN-PROGRESS
Default Severity: NA
Logical Object: EQUIPMENT
The OTDR-HYBRID-FAR-END-IN-PROGRESS alarm is raised when a hybrid scan is started on the remote
side.
Clear the OTDR-HYBRID-FAR-END-IN-PROGRESS Alarm
Step 1
Wait until the scan on the remote side is completed.
The time varies depending on the type of scan.
Step 2
Alternatively, stop the scan by navigating to: Maintenance->DWDM->OTDR; select the side where the scan is ongoing
and click Cancel. The scan is stopped on both the sides.
If the alarm does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).