Specifications And Panel Wiring; Specifications - Honeywell IP-AK2 Installation And Configuration Manual

Access control unit
Table of Contents

Advertisement

Specifications and Panel Wiring

6 Specifications and Panel Wiring

Specifications

Specification
Relay Contacts
Reader Interface
Maximum Output Loading
Common Connections
Mechanical
Environment
Cable
48
Parameters
Four Form-C SPDT relays, 3A @ 28VDC (external PTC preferred)
Voltage: 12VDC nominal
Power
Current: 300mA combined with two readers
LED Output
Open collector driver capable of sinking up to 8mA
Tamper
Supervised or non-supervised input
Data Input
TTL compatible inputs
Buzzer Output
Open collector driver capable of sinking 8mA at 12VDC
Honeywell JT-MCR MIFARE Smart READERS
Honeywell HON-MSR MIFARE SECTOR READERS
Reader Type
HONEYWELL OmniProx PROXIMITY READERS
Honeywell OmniClass SMART READERS
Honeywell HON-FIN3000 Fingerprint
Reader
150mA (any of the two reader outputs)
150mA (battery charge current for the battery wired in
Battery
series)
Total
300mA (combined current of the two reader outputs)
The common connections of supervised input are all connected internally. They are
not connected to the panel chassis.
The common connections of relay output are NOT all connected internally, which are
NOT connected to the panel chassis.
Height: 340mm (13.4inches)
Enclosure Dimension
Width: 290mm (11.4inches)
Depth: 78mm (3.1inches)
Enclosure Weight
5Kg (11lbs), with one battery
Operating: 0˚C ~ 50˚C
Temperature
Storage: -55˚C ~ +85˚C
Humidity
5% ~ 85% RHNC
Shield, cat5 to RJ-45
Ethernet
(Maximum 10 panels)
Readers
7-Conductor, Shielded
Supervisor Input
Twisted Pair, Shielded
Relay Outputs
Twisted Pair, Shielded
330inches (100m)
(Maximum Distance)
500 inches (153 m)
(Maximum Distance)
2,000 inches (610 m)
(Maximum Distance)
2,000 inches (610 m)
(Maximum Distance)