8 Maintenance
Midas
is a fully serviceable product designed with
®
modular components that can be readily replaced
by trained service personnel so as to minimize the
time that the gas detector is not available.
External in-line air filters should be replaced every
three months or more frequently if the system is
sampling in environments that have high levels of
particulate matter or very acidic / wet atmospheres.
Similarly, the internal particulate filter should be
replaced once a year or more frequently if the
sample lines are prone to heavy contamination.
Every sensor cartridge is shipped with a 12 month
warranty and an extended 2 year warranty sensor
cartridge is also available for purchase. All sensor
cartridges are factory calibrated to traceable
national standards before shipment to the end user.
Note that testing or calibrating with the wrong
(incorrect, out of date, non-traceable) calibration
gases, calibration equipment, methods or operating
conditions can actually damage the sensor
cartridge's lifetime and alter the calibration
adversely. Only qualified calibration technicians
should attempt to calibrate the Midas
Note
For details regarding sensor cartridge
calibration and bump testing method refer
to
Section
17.
The internal pump module is designed to operate
for a minimum of 24 months and it is recommended
that this pump module (part number MIDAS-A-007)
be replaced every 2 years.
Pump
Pyrolyzer (all models)
Internal Filter
External Sample Line Filter 780248
Leak Check
Bump Test
Flow Calibration
See
Appendix B
your application.
Note
gas detector.
®
8-2
Midas
Gas Detector
®
Recommended Maintenance Schedule
Component
2 years/as needed
1 year
2 years/as needed
1991-0147
1830-0055
1830-0027
Leak Check every 6 months
or after pump, pyrolyzer or
internal filter replacement.
6 months
Flow Calibrate after pump,
pyrolyzer or internal filter
replacement.
for the correct filter requirement for
The CO2 cartridge MIDAS-S/E-CO2 bias
battery will last only about 9 months. After
replacement, allow at least a day for the
cartridge to reach equilibrium.
Frequency
3-6 months
3-6 months
3-6 months
1 month