Clean Boot the Computer

In some cases where the computer completely stops responding, it may be necessary to
perform a clean boot. Because clean booting may result in data loss, use this method
only if all other recovery methods have failed. This returns the computer back to its fac-
tory default settings.
Note: Clean booting the device erases all files in the ObjectStore including any file or registry
changes. Any files that are present in the \System folder are preserved.
1. Tap Start > Settings > Control Panel > Registry.
2. Tap the Load Factory Defaults button.
Disconnect the UPS Battery
If the CV41 stops responding, or you plan on shipping the CV41, you need to disconnect
the UPS battery.
1. Remove the CV41 from the smart dock. For help, see
2. Using a Phillips head screwdriver, remove the two screws that secure the SIM card
3. Press the UPS Battery Disconnect button located below the SIM card slot.
4. Reinstall the SIM card access panel and tighten the screws to a torque to a value of
Once power external power is reconnected to the CV41, the UPS battery automatically
reconnects.
76
Smart
Dock.
access panel.
4-5 in/lbs.
CV41 Vehicle Mount Computer (Windows CE) User Guide