Honeywell SmartDrive Compact User Manual page 72

Table of Contents

Advertisement

Honeywell
Ambient operating
temperature
Storage temperature
Relative humidity
Air quality:
- chemical vapours
- mech. particles
Ambient
Altitude
conditions
Vibration:
EN60068-2-6
Shock
IEC 68-2-27
Enclosure class
Immunity
EMC
Emissions
Standards
Certificates
and
manufacturer's
declarations of
conformity
Table 10.1 : SmartDrive Compact technical data
Technical Data
-10°C (no frost)...+50°C: rated loadability I
-40°C...+70°C
0...95% RH, non-condensing, non-corrosive, no
dripping water
IEC 721-3-3, unit in operation, class 3C2
IEC 721-3-3, unit in operation, class 3S2
100% load capacity (no derating) up to 1000m.
1% derating for each 100m above 1000m; max.
2000m
3...150 Hz
Displacement amplitude 1(peak) mm at 3...15.8
Hz Max acceleration amplitude 1 G at 15.8...150
Hz
UPS Drop Test (for applicable UPS weights)
Storage and shipping: max 15 G, 11 ms
(in package)
IP20
Complies with EN50082-1, -2, EN61800-3
Complies as standard with EN61800-3 category
C2 (Honeywell level H: normal public electricity
network requirements). Category C1with exter-
nal EMC-filter (Honeywell level C: special
requirements for installations in extremely sensi-
tive areas)
For EMC: EN61800-3,
For safety: UL508C, EN61800-5
For safety: CB, CE, UL, cUL,
For EMC: CE, CB, c-tick
(see unit nameplate for more detailed approvals)