Periodic Inspection And Cleaning - Cisco 1100 Series Hardware Installation Manual

Integrated services router
Hide thumbs Also See for 1100 Series:
Table of Contents

Advertisement

Periodic Inspection and Cleaning

Description
Operating humidity
Operating temperature
Altitude in China
Altitude in all other countries
Transportation and Storage
Nonoperating temperature
Nonoperating humidity
Nonoperating altitude
Periodic Inspection and Cleaning
Periodic inspection and cleaning of the external surface of the router is recommended to minimize the negative
impact of environmental dust or debris. The frequency of inspection and cleaning is dependent upon the
severity of the environmental conditions, but a minimum of every six months is recommended. Cleaning
involves vacuuming of router air intake and exhaust vents.
Sites with ambient temperatures consistently above 25°C or 77°F and with potentially high levels of dust
Note
or debris might require periodic preventative maintenance cleaning.
Hardware Installation Guide for the Cisco 1100 Series Integrated Services Router
14
Overview of Cisco 1000 Series Integrated Services Routers
Specification
5 to 85% relative humidity
32 to 104°F (0 to 40°C) Sea Level;
32 to 77°F (0°C to 25°C) at 10,000 ft
1.5°C derating per 1000 ft
0-6560 ft (0-2000 m)
0-10,000 ft (0-3050 m)
-40 to 158°F (-40 to 70°C)
5 to 95% relative humidity (noncondensing)
0 to 15,000 ft (0 to 4570m)