Honeywell S8610U Quick Reference Manual page 2

Universal intermittent pilot gas ignition control

Advertisement

Table 4. green led Status codes. (continued)
6+3
On every 6th flame
Initiate new trial
Check gas supply,
failure during run on
for ignition after
pilot burner, flame
the same "Call for
retry delay
sense wiring,
Heat."
completed.
contamination of
flame rod, burner
ground
connection.
6+4
Flame sensed
Control module
Check for pilot
out of sequence
waits until flame
flame. Replace
for longer than 10
is no longer
gas valve if pilot
seconds.
sensed and then
flame present.
goes to soft
If no pilot flame,
lockout. Flash
cycle "Call for
code continues.
Heat." If error
Control module
repeats, replace
auto resets from
the S8610U con-
soft lockout after
trol module.
one hour.
ON
Soft lockout due
Control module
Reset by cycling
to error detected
auto resets from
"Call for Heat."
during self check
soft lockout after
If error repeats,
sequences.
one hour.
replace the
S8610U control
module.
a
Flash Code Descriptions:
- Flash Fast: rapid blinking.
- Heartbeat: Constant 1/2 second bright, 1/2 second dim cycles.
- A single flash code number signifies that the LED flashes X
times at 2 Hz, remains off for two seconds, and then repeats the
sequence.
- X + Y flash codes signify that the LED flashes X times at 2 Hz,
remains off for two seconds, flashes Y times at 2Hz, remains off for
three seconds, and then repeats the sequence.
7
Table 5. conversion from honeywell intermittent Pilot modules.
Replacement
Control
Old Control
S90A,B
S8600A,B,C
S8610A,B,C
S8610U1003
S8620C,
S8660D,J
Terminal
S8670D,J
Function
S8610U
S86A,C S86B,D S86E,F,G,H
S8680D,J
Main Valve
MV
MV
MV
MV
MV
Operator
Main Valve and
MV/PV
MV/PV MV/PV MV/PV
MV/PV
Pilot Common
Pilot Valve
PV
PV
PV
PV
PV
Operator
Burner Ground
GND
GND
GND
GND
GND
Connection
(BURNER)
(BURNER)
(BURNER)
Transformer
24V GND
25V (2) 25V
25V (2)
a
24V GND
Secondary (un-
switched leg)
Transformer
24V *
25V (2) 25V
25V (2)
a
*
24V *
Secondary
25V (2) or 24V used only in systems
(switched leg)
where plug-in cable connects damper to
module
TH-W
TH-R
b
TH-R
b
TH-R
b
TH-W
(This ter-
c
c
TH-W
TH-W
TH-W
minal is not
included on
S90.)
d
e
e
e
d
Flame Sensor
SENSE
SENSE
f
Igniter /Sensor SPARK
IGN
IGN
IGN COIL
SPARK
COIL
f
COIL
f
a
Terminals may be marked 25V on some models and 24V on later models. These are functionally equivalent.
b
If 25V (2) and TH-R have wires connected, disconnect and splice together with solderless connector.
c
If TH-R and TH-W are jumpered together, connect 25V (2) lead from S86 to TH-W on S8610U.
d
On dual igniter and sensor models, remove jumper wire quick connect from S8610U Remote Sense terminal, then cut jumper wire at circuit
board and discard.
e
Leave black jumper connected.
f
Use Rajah to quick connector adapter (supplied) or cut Rajah connector off ignition cable at module end and attach insulated quick connect for
connection to S8610U.
8
Procedural Notes
S8600F,H,M
S8610F,H,M
S8660E,K
S8670E,K
MV
MV/PV
PV
GND
(BURNER)
24V GND
24V *
* Important
If the old module had a vent damper connec-
tor but a vent damper was not installed, or if
it did not have a vent damper connector, then
connect the 25V (2) or 24V wire from the old
module to the TH-W terminal on the S8610U.
Do not use the 24V terminal on the S8610U.
TH-W
If the old module had a vent damper, connect
it to the P1 connector on the module, and
wire the terminals as indicated in Table 1.
e
SPARK
9
automation and control Solutions
Honeywell International Inc.
Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North
35 Dynamic Drive
Golden Valley, MN 55422
Toronto, Ontario M1V 4Z9
http://yourhome.honeywell.com
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
® U.S. Registered Trademark.
© 2006 Honeywell International Inc.
69-2042 M.S. 12-06
S8610u universal
intermittent Pilot gas
ignition control
Technician'S Quick reference guide
The following service procedure provides a quick overview for
the S8610U series control. For more information, refer to form
69-1955.
wiring connecTionS
SPARK
TH-W (OPT.)
REMOTE
MV
24V (OPT.)
SENSE
MV/PV
SENSE
PV
JUMPER
BRN/GND
WIRE
24V GND
P1 VENT DAMPER
P4 JUMPER
CONNECTOR
P2 ECOM
M23615
fig. 1. Typical wiring connections.
69-2042