ISSUE 1.0
82-05 : ISDN BRI & PRI Layer2 (S-Point) Initial Data Setup
Level
MF
Description
Use Program 82-05 : ISDN BRI & PRI Layer2 (S-Point) Initial Data Setup to set the basic data for
the Layer 2 of ISDN BRI/PRI S-Point.
Input Data
Item No.
01
02
03
04
05
06
07
Conditions
None
Feature Cross Reference
None
Programming Manual
Downloaded from
www.Manualslib.com
Program 82 : Basic Hardware Setup for
Item Name
Timer T200
Timer T201
Timer T202
Timer T203
N200
N201
N202
manuals search engine
Input Data
1 ~ 255 (100 ~ 25500 ms)
1 ~ 255 (100 ~ 25500 ms)
1 ~ 255 (100 ~ 25500 ms)
1 ~ 255 (100 ~ 25500 ms)
1 ~ 255
1 ~ 65535 (Byte)
1 ~ 255
SL1000/SL1100
Extension
Program
82
Default
10 (1 sec)
10 (1 sec)
20 (2 sec)
100 (10 sec)
3
260
3