Installation
On the front of the rack, place the screws in the appropriate holes of
thesupport upright and screw the sliding rails tight at the 19" profiles on
the front.
Figure 7: Position of the cage nuts (front side of the rack, left support upright as example)
Place the cage nuts for fastening the subsystem in the appropriate holes
of the front support uprights.
Put the subsystem on the support angles of the sliding rails and push
the subsystem into the rack as far as it will go.
The following steps can be performed by a single person:

Figure 8: Fastening the Storage Subsystem

Secure the subsystem within the rack using the two screws on each
side.
Cisco C880 M4 Storage Subsystem Operating Manual for Server with E7-8800 v3 CPU
Installing the Storage Subsystem in the Rack