FIELD
TITLE and DATA ENTRIES
2∗ ∗ ∗ ∗ 07
Auto-Disarm Delay (partition-
specific)
00 = no delay.
01-14 times 4 minutes (04-56) delay.
15 = no auto disarming.
2∗ ∗ ∗ ∗ 08
Force Arm Enable for Auto-Arm
(partition-specific)
0 = disable
1 = enable
2∗ ∗ ∗ ∗ 09
Open/Close Reports by
Exception (partition-specific)
0 = disable
1 = enable
2∗ ∗ ∗ ∗ 10
Allow Disarming Only During
Arm/Disarm Windows (partition-
specific)
0 = disable
1 = enable
2∗ ∗ ∗ ∗ 11
Allow Disarm Outside Window if
Alarm Occurs
0 = disable
1 = enable
2∗ ∗ ∗ ∗ 18
Enable GOTO for this Partition
(partition-specific)
0 = disable
1 = enable
2∗ ∗ ∗ ∗ 19
Use Partition Descriptor
0 = disable
1 = enable
2∗ ∗ ∗ ∗ 22
Display Fire Alarms of Other
Partitions (partition-specific)
0 = disable
1 = enable
2∗ ∗ ∗ ∗ 23
Display Burg, Panic and CO
Alarms for Other Partitions
(partition-specific)
0 = disable
1 = enable
2∗ ∗ ∗ ∗ 24
Display Troubles of Other
Partitions (partition-specific)
0 = disable
1 = enable
5-12
EXPLANATION
This is the time between the end of the disarming window and the start of auto
disarming of the system.
If enabled, the system automatically bypasses any faulted zones when it
attempts to auto-arm.
If disabled, the system will not auto-arm.
Force Arming is not a ULC Listed feature and
U LC
must be disabled for ULC installations.
If enabled, Open/Close reports are sent only if the openings/closings occur
outside the arm and disarm windows.
NOTES:
Open reports are also suppressed during the closing window in order to
prevent false alarms if the user arms the system, then re-enters the premises,
for example to retrieve a forgotten item.
Openings and closings are still recorded in the event log.
If enabled, disarming of the system is allowed only during the
arming/disarming windows, or if the system is in alarm (if 2∗11 is set to 1).
NOTE: This applies only to Operator-level users. Installer, Master, and
Manager-level users can disarm the system at any time.
NOTE: Duress users behave the same way as Operator-level users.
If enabled, allows the system to be disarmed outside the programmed disarm
(opening) window if an alarm has occurred. Otherwise disarming is allowed
only during the disarm window.
NOTE: Used only if field 2∗10 is enabled.
If enabled, this partition can be accessed from another partition's keypad
using the GOTO command.
If enabled, the normal keypad display will include a partition number and four-
digit descriptor.
If enabled, allows fire alarms that occur on other partitions to be displayed at
this partition's keypad(s).
If enabled, allows burglary, panic and CO alarms that occur on other partitions
to be displayed at this partition's keypad(s).
If enabled, allows troubles that occur on other partitions to be displayed at this
partition's keypad(s).