Honeywell VISTA-128BPT Installation And Setup Manual page 12

Commercial burglary partitioned security system with scheduling
Hide thumbs Also See for VISTA-128BPT:
Table of Contents

Advertisement

VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
Downloading
Supports upload and download capability.
Can be downloaded via the following 7847i, 7847i-E, GSMV, GSMX, GSMHS, IGSMV, or IGSMHS using Compass
revision 1.5.8 or above.
Can download access control cardholder information.
Event Log
Provides an event log (history log) that can store up to 1000 events (512 for VISTA-128BPT).
Can view the event log on an alpha or graphic/touch-screen keypad.
Telephone Line Fault Monitor
This feature is enabled in field *30. The panel will indicate "PHONE LINE CUT" on the keypad when phone line
voltage drops below 2VDC for approximately 120 seconds. The panel will send/log CID code E351 Telco Fault over
ECP Communicator. (Please note that the E351 report needs to be enabled in System Group 2, report code
programming under "TELCO TROUBLE".) R351 Telco Fault is sent/logged when phone line voltage has returned
for approximately 60 seconds.
®
V-Plex
Smart Contact Technology
Automatic suppression of fault/restores when disarmed: Smart V-Plex
IS2500SN polling loop motion detectors can be set to stop sending fault/restore signals while the partition is
disarmed. This prevents the polling loop from slowing down due to high bus activity in busy areas. The feature
is enabled by Zone in Zone Programming.
When enabled, within about 5 minutes of program exit, the panel will send the command to the Smart Contacts
to turn off their LED and stop sending faults/restores to the system. (The DT-7500SN and IS2500SN will turn
off their LED unless the LED DIP switch is set to ON, in which case the LED will always remain enabled.)
Automatic Test Mode entry: Upon entering Code + 5 (Burglary Walk Test Mode), the panel will again tell the
PIR to enable the LEDs and start sending faults/restores. The LED will remain enabled until the Burglary Walk
Test mode is exited. Removing and replacing the cover of the DT7500SN and IS2500SN, or power-cycling these
sensors will also put them in the walk test mode, enabling the LEDs and sending of faults/restores for 10
minutes.
NOTE: Regardless of Smart Mode, Tamper and Supervision Failures are sent without delay.
PIR Anti-Mask:
panel when the lens has been blocked. For DIP switch settings related to this feature, refer to the motion
detector documentation. Anti-Mask can be enabled in zone programming if a zone type 04 (interior) or 10
(interior with delay) and input type 06 (serial poll) are selected. In the event masking occurs, the message "PIR
masked" will be displayed on the keypad, and a trouble report code is used to report the masking.
Smoke Detector Maintenance:
5193SD and 5193SDT V-Plex detectors, as well as the 5808W3.
Operation: When programmed as a "Smart Contact" in zone programming, a sensor which is capable of
providing a high or low sensitivity condition (e.g., sensor is dirty) will trigger a message on the keypad, a dialer
report, and an event log entry. The display message will indicate HSENSxxx or LSENSxxx, where xxx is the
zone number.
Additional Features
Provides up to 60 installer-defined, custom words that can be used for zone descriptors.
Provides 32 keypad macro commands (each macro is a series of keypad commands of up to 32 keystrokes) using the
A, B, C, and D keys by partition.
Provides cross-zone capability, which helps prevent false alarms by preventing a zone from going into alarm unless
its cross-zone is also faulted within a 5-minute period.
Contains a built-in User Manual, which provides the end user with a brief explanation of the function of a key when
the user presses any of the function keys on the keypad for 5 seconds.
Provides an RS232 input (TB4) for serial data. This is useful for interfacing the system with Automation software.
Automation software cannot be used if a serial printer is used on the system.
1-4
Some motion detectors such as the DT7500SN have an "Anti-Mask" feature that will alert the
Provides Maintenance Signal support for certain smoke detectors, such as the
®
sensors such as the DT7500SN, and

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-250bptVista-128bptsia

Table of Contents