AH-S22AW2
AH-S25AW2
(3) Installation dimensions
80
Center of left
piping hole
75
Profile of indoor unit
750
590
400
D
E
B
Stamp mark
A
ø70 piping hole
60 135
75
90
C
265
450
100
A
80
B
Edge
C
D
Lintel
E
Center of rear piping hole
4
Unit: mm
The front position of auxiliary pipe is
stamped on the installation plate.
It is used as a position mark when the
piping is connected.
At a distance equal to the scale
stamped on the installation plate
you will find the center of rear piping
hole. Engage the measure with the
front holder of scale, and measure the
distance.
For ø65, shift the center down by 3
mm, and makle a hole.
The triangular dents (2 places) in the
center are for center positioning. which
are usable for installing.
The hole in the center upper part has
-shape. After tentatively tightening
the screw, it is possible to ergage the
installation plate here.