Sharp AH-S22AW2 Service Manual page 15

Table of Contents

Advertisement

12
11
10
9
8
7
6
5
4
3
2
i zone
1
0
1
Operating frequency code
12
11
10
9
8
7
6
5
4
3
2
1
Operating frequency code
1-3 Automatic operation
The operating mode and temperature setting are
determined by the room temperature and the external
air temperature.
Cooling
(25˚C)
26
Dry
(Room temperature
- 2°C)
21
Room
temperature
(˚C)
1-4 ON-timer
The ON-timer is set by pressing the ON-timer button.
In order to attain the set temperature at the set time,
the operation starting time is corrected by neuro and
fuzzy computing one hour before the set time.
Dry
e, f zone
g zone
h zone
2
3
4
Circulation
High
Med
Low
0
31
34
Cooling
Cooling
(26˚C)
(27˚C)
1-5 OFF-timer
The OFF-timer is set by pressing the OFF-timer
button. Operation is as follows:
Cooling
By fuzzy computing
Set the shift up time
Final(Cooling setting + 1°C)
Dry
Same as above
(Final setting + 1°C)
*During Cooling / Dry
1°C
1
hour
Timer operation starts
1-6 Swing louvre
The louvre is moved by a stepping motor to perform
swing and fixing in the set position.
If the "FLOW DIRECTION" button is prossed during
swing, it will stop. If the "FLOW DIRECTION" button is
prossed while it is stopped, it will swing.
1-7 Restart control
Once the compressor stops, this control prevents it
from starting again for 3 minutes. It also prevents
starting for 20 seconds immediately following plugging
into the power outlet.
1-8
One-hour operation
If this button is pressed when operation is
stopped, operation will begin and then stop after 1
hour.
If pressed when it is operating, will stop after one
hour.
1-9
Full power operation
Immediately begins cooling at maximum power
and air flow. Full power stops after 1 hour.
Operates at setting of 18°C.
1-10
Power ON start
If a jumper wire is inserted into the place indicated
JP99 on the indoor control board, and the power
plug is inserted. cooling will be automatically
determined by the room temperature sensor on
the main unit, and operation will begin.
15
Set temperature
Timer set time
Room
temperature
Stops
AH-S22AW2
AH-S25AW2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ah-s25aw2Au-s22aw2Au-s25aw2

Table of Contents