Makita LS1040 Instruction Manual page 6

Hide thumbs Also See for LS1040:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
-1
No load speed (min
)
Dimensions (L x W x H)
Net weight
Safety class
• Due to our continuing program of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
Symbols
The following show the symbols used for the equipment.
Be sure that you understand their meaning before use.
Read instruction manual.
DOUBLE INSULATION
To avoid injury from flying debris, keep
holding the saw head down, after
making cuts, until the blade has come
to a complete stop.
Do not place hand or fingers close to
the blade.
For your safety, remove the chips,
small pieces, etc. from the table top
before operation.
Always set SUB-FENCE to left position
when performing left bevel cuts. Failure
to do so may cause serious injury to
operator.
To loosen the bolt, turn it clockwise.
Only for EU countries
Do not dispose of electric equipment
together
material!
In
observance
Directive,
Electronic
implementation in accordance with
national law, electric equipment that
have reached the end of their life must
be collected separately and returned to
an
recycling facility.
Intended use
The tool is intended for accurate straight and miter
cutting in wood. With appropriate saw blades, aluminum
can also be sawed.
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
with
household
of
the
European
on
Waste
Electric
Equipment
and
environmentally
compatible
END217-5
For Model LS1040
For public low-voltage distribution systems of
between 220 V and 250 V.
Switching operations of electric apparatus cause
voltage fluctuations. The operation of this device under
unfavorable mains conditions can have adverse effects
to the operation of other equipment. With a mains
impedance equal or less than 0.29 Ohms it can be
presumed that there will be no negative effects. The
mains socket used for this device must be protected
with a fuse or protective circuit breaker having slow
tripping characteristics.
Noise
The
typical
according to EN61029:
Sound pressure level (L
Sound power level (L
Uncertainty (K) : 3 dB (A)
Vibration
The
vibration
waste
determined according to EN61029:
Vibration emission (a
Uncertainty (K) : 1.5 m/s
and
its
The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.
The declared vibration emission value may also be
used in a preliminary assessment of exposure.
ENE004-1
WARNING:
The vibration emission during actual use of the
power tool can differ from the declared emission
value depending on the ways in which the tool is
used.
ENF002-2
Be sure to identify safety measures to protect the
operator that are based on an estimation of
exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it
is running idle in addition to the trigger time).
6
530 mm x 476 mm x 532 mm
A-weighted
noise
level
) : 91 dB (A)
pA
) : 101 dB (A)
WA
Wear ear protection
total
value
(tri-axial
2
) : 2.5 m/s
h
2
4,600
12.4 kg
/II
ENF100-1
ENG905-1
determined
ENG900-1
vector
sum)
or less