event fanbad

S e n d c o m m e n t s t o n e x u s 3 k - d o c f e e d b a c k @ c i s c o . c o m
event fanbad
To specify an event criteria for an Embedded Event Manager (EEM) applet that is run on the basis of a
fan bad event, use the event fanbad command. To remove the fan bad event criteria, use the no form of
this command.
Syntax Description
fan number
time interval
Defaults
None
Command Modes
Embedded event manager configuration mode
Command History
Release
5.0(3)U3(1)
Usage Guidelines
This command does not require a license.
Examples
This example shows how to specify that an EEM applet runs when a fan bad event occurs:
switch# configure terminal
switch(config)# event manager applet bad-applet
switch(config-applet)# event fanbad time 1200
switch(config-applet)#
Cisco Nexus 3000 Series NX-OS System Management Command Reference
-SM-58
event fanbad fan number time interval
no event fanbad [fan number] time interval
Specifies a fan number to monitor for a fan bad event. The range is from 1 to 1.
Specifies the time interval (in seconds) within which the fan can stay bad. The
range is from 10 to 64000.
Modification
This command was introduced.