Important Points to Remember
•
Link dampening is not supported on VLAN interfaces.
•
Link dampening is disabled when the interface is configured for port monitoring.
•
You can apply link dampening to Layer 2 and Layer 3 interfaces.
•
You can configure link dampening on individual interfaces in a LAG.
Enabling Link Dampening
To enable link dampening, use the following command.
•
Enable link dampening.
INTERFACE mode
dampening
Examples of the show interfaces dampening Commands
To view the link dampening configuration on an interface, use the show config command.
R1(conf-if-gi-1/1)#show config
!
interface GigabitEthernet 1/1
ip address 10.10.19.1/24
dampening 1 2 3 4
no shutdown
To view dampening information on all or specific dampened interfaces, use the show interfaces dampening command from EXEC
Privilege mode.
Dell#show interfaces dampening
Interface
Supp
State
Gi 1/2
Up
Gi 1/2
Up
Gi 1/3
Up
Dell#
To view a dampening summary for the entire system, use the show interfaces dampening summary command from EXEC
Privilege mode.
Dell# show interfaces dampening summary
20 interfaces are configured with dampening. 3 interfaces are currently suppressed.
Following interfaces are currently suppressed:
Gi 1/2
Gi 3/1
Gi 4/2
Dell#
Clearing Dampening Counters
To clear dampening counters and accumulated penalties, use the following command.
•
Clear dampening counters.
clear dampening
346
Interfaces
Flaps
Penalty Half-Life
0
0
1
0
0
1
0
0
1
Reuse
Suppress
2
3
2
3
2
3
Max-Sup
4
4