Influencing Management Unit Selection On A Stack - Dell S3048-ON Configuration Manual

Hide thumbs Also See for S3048-ON:
Table of Contents

Advertisement

Speed in RPM
Dell#
The following is an example of the show system brief command to view the stack summary information.
Dell#show system brief
Stack MAC
Reload-Type
--
Stack Info
--
Unit
UnitType
------------------------------------------------------------------------------------
1
Member
2
Member
3
Management
4
Member
5
Member
6
Member
--
Power Supplies
Unit
Bay
Status
---------------------------------------------------------------------------
3
1
up
3
2
absent
--
Fan
Status
--
Unit Bay
TrayStatus
------------------------------------------------------------------------------------
3
1
up
3
2
up
3
3
down
Speed in RPM
Dell#
The following example shows the show system stack-ports command.
Dell#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin
------------------------------------------------------------------
1/56
3/56
1/60
3/60
3/48
3/52
3/56
0/56
3/60
0/60

Influencing Management Unit Selection on a Stack

Stack priority is the system variable that Dell Networking OS uses to determine which units in the stack are the master and standby
management units. If multiple units tie for highest priority, the unit with the highest MAC address prevails.
If management was determined by priority only, a change in management occurs when:
the management unit is powered down or a failover occurs.
you disconnect the management unit from the stack.
When the management unit fails, the unit disappears from the stack topology. At that time, the standby unit detects the communication
loss and switches from the standby unit role to the management unit role in the stack. From the remaining units in the stack, the system
selects a new standby unit based on the unit priority using the same algorithm used when the stack was initially created. When the failed
unit recovers, it takes the next available role, usually that of a stack member.
: 00:12:13:34:12:40
: normal-reload [Next boot : normal-reload]
Status
ReqTyp
not present
S3048-ON
not present
online
S3048-ON
not present
not present
not present
--
Type
FanStatus
AC
up
absent
Fan0
Speed
up
18000
up
18000
(Gb/s)
Status Status Group
40
up
40
up
40
up
40
up
40
up
40
up
CurTyp
S3048-ON
FanSpeed(rpm)
8032
0
Link
Trunk
up
up
down
down
up
up
Version
Ports
9.8(0.0P2)
52
Stacking
815

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents