Yamaha MMP1 Operation Manual page 34

Hide thumbs Also See for MMP1:
Table of Contents

Advertisement

4-1-8g. Global tab/General
Configure general settings to be used across all Scenes here.
Word Clock Source
Use scene 1 button for
all mute mode
Monitor Level/Mute/
Dim at launch
Mute
-∞
Current
Monitor Level/Mute/
Dim at Scene Recall
Mute
-∞
Current
Resume
Dim main monitor while
talkback is on
Click to select a word clock source for the MMP1 unit. The sync status with each word clock source
will also appear here.
Set this to use the SCENE [1] key on the front panel of the MMP1 unit as an all mute key. Press the all
mute key to mute all output signals.
NOTE
Scene 1 will not change even if the all mute key is set. This Scene can be recalled from the MMP1
Editor menu bar.
Select the monitor level, dimmer and mute status for the time of MMP1 power activation.
Activates when Mute is on at the time of MMP1 power activation. The monitor level and dimmer
settings are restored to what they were when turning off the MMP1.
Activates when the monitor level is set to -∞ at the time of MMP1 power activation. The mute and
dimmer settings are restored to what they were when turning off the MMP1.
At the time of MMP1 power activation, the monitor level, mute and dimmer settings are restored to
what they were when turning off the MMP1.
Select the monitor level, dimmer and mute status for the time of Scene recall.
Recalls when Mute is on at the time of Scene recall. The monitor level and dimmer settings are
restored to what they were when the Scene was stored.
Recalls when the monitor level is set to -∞ at the time of Scene recall. The mute and dimmer settings
are restored to what they were when the Scene was stored.
At the time of Scene recall, the monitor level, dimmer and mute settings are restored to what they were
when the Scene was stored.
When recalling the Scene, the monitor level, dimmer and mute settings are kept as the same setting at
the time of Scene recall, regardless of the monitor level, dimmer and mute settings stored to the
Scene.
The Main Monitor dimmer is turned on when Talkback is on.
4. Screens
MMP1 Operation Manual
34

Advertisement

Table of Contents
loading