Slide the optional drive cage assembly partially into the server chassis.
7.
Connect the cabling to the hard drive cage.
8.
Item
Description
Connect both mini-SAS cables to the HP Smart Array SAS
1 and 2
RAID Controller card connector
Connect the power cable
3
Connect the I
4
Slide the drive cage assembly fully into the server chassis and install the four screws.
9.
Install the hard drives and hard drive blanks in the hard drive cage.
10.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
2
C cable
Removal and replacement procedures 36