Quadrature speed and direction sensors

Advertisement

Quadrature Speed and Direction Sensors
SNG-Q Series
Figure 5. SNG-QPRA-000 Mounting Dimensions (For reference only: mm/[in].)
2,0
[0.08]
31,77
[1.25]
13,80
[0.54]
5,85
[0.23]
66,0 Max.
[2.60]
15
[0.59]
ø
6,20
[0.24]
3
[0.12]
108.5°
5,00
[0.20]
4,50
[0.18]
2,50
[0.10]
ø
13,90
[0.55]
ø
14,95
[0.59]
Vs: Pin D
Power
Supply
(4.5 V to 26 V)
Ground: Pin A
Note: The load resistor values should be such
that the output current does not exceed the
maximum load current of 40 mA.
Use Ohm's Law to calculate the load resistor
based on the supply/load voltage used:
R = V / 0.04 A
(mating connector is Amp Superseal 1.5 282088)
Pin A
Ground
8,50 - 9,00
[0.33 - 0.35]
34,95
[1.38]
32309314
Circuit Diagram
Channel B: Pin C
Channel A: Pin B
Amp Superseal 1.5 Connector Pinout
Pin B
Pin C
Channel A Channel B