Honeywell NEXPTZ-PD Installation And Operation Manual

Nexptz series explosion proof security camera (high speed standard type)

Advertisement

INSTALLATION & OPERATION GUIDE BOOK
NEXPTZ Camera
Explosion proof Security Camera
(High Speed Standard Type)
- 1 -

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell NEXPTZ-PD

  • Page 1 INSTALLATION & OPERATION GUIDE BOOK NEXPTZ Camera Explosion proof Security Camera (High Speed Standard Type) - 1 -...
  • Page 2: Important Safety Instructions

    Important Safety Instructions Install and use this system after reading these instruction thoroughly. Keep these instructions. Install in accordance with the manufacture’s instruction. Take care of all Cautions and Warnings. Use stainless steel hardware to fasten the mount to outdoor surfaces. Only use replacement parts recommended by the manufacturer.
  • Page 3: Methods Of Installation

    Methods of Installation This system can be installed in a standard or inverted position or camera Housing only with optional bracket as below Figure1. When installed for inverted operation, the origin of camera shall be reconfigured through the Camera function. There is no need to be adjusted physically but sunshield bracket may not be functional at this case.
  • Page 4 Methods of Installation Figure2. Install the product to Pedestal Mount bracket To install this product, please refer to Figure2 and do the following steps. 1. Make sure the threads of the product and the threads of the supplied M8X15mm stainless steel bolts (Supplied) are free of dirt and debris.
  • Page 5 Methods of Installation Sealing Fiber Filler compound Cables Sealing Method Explosion proof PT 3/4”-14 Nipple Flexible conduit PT 3/4 “-14 (Supplied) (Not Supplied) Seal Fitting (Not Supplied) Figure3. Install Product to the surface with Pedestal mount bracket To install this product, please refer to Figure3 and do the following steps. 1.
  • Page 6: Base Schematic

    Base Schematic POWER AC110 or 220V RS 485 RS 485 Alram out MAIN MONITOR FRONT RS 485 DATA 2 DATA 1 DC 12V SLAVE 1 DOME 2 RS 232C ALARM/DVR REAR DATA1 DATA2 DC 12V REAR KEYBOARD CONTROLLER HTX-5000 Figure4. Base Schematic of Installation 1.
  • Page 7: Cable Configuration

    Cable Configuration Alram In/Out Put POWER (AC 220V or 110V) RS-485 Data+, - 2m ± 0.3m Figure8. Cable configuration Configuration of Wire Harness Wire Color Function Description Brown Power Input Sky Blue (AC 100V ~ 240V) Green Alarm 1 Orange Alarm 2 Yellow Alarm Input...
  • Page 8 Key Feature and Introduction The NEXPTZ Series camera which is Explosive proof camera features a high resolution Super HAD CCD imager for enhanced lowlight sensitivity. The NEXPTZ Series follow the stringent explosion-proof requirements with creative mechanical strength and design. Moreover, the NEXPTZ explosion-proof system is designed to meet the rigorous requirements of explosion- proof electrical equipment installed in hazardous locations.
  • Page 9: Simple Function Control Guide

    Simple Function Control Guide * This function is specialized to HTX-5000 keyboard. Function Process Results Remarks For matching ID 01 ① Press PAN/TILT (CAM) button If ID set 02, press (Cam) in sequence. button ② Move Joystick to the right, You can see the moving as following the left, up and down.
  • Page 10 Simple Function Control Guide Function Process Results Remarks (Enter) ① Press (Menu) button. -Menu screen is displayed. = (94+ Preset) (95+ Preset) at Pelco Protocol at Pelco protocol -Go into the sub-menu items. ② Move Joystick to the right (Menu) Change value.
  • Page 11: Program And Operation

    Program and Operation Principle of joystick usage in the programming (editing) mode * This function is specialized to HTX-5000 keyboard. Button or Joystick movement in menu Function Go into the sub-menu items. Execute the command(exit) Joystick left or right Change value. Navigate through the menu items.
  • Page 12 Program and Operation MENU TREE 1. FUNCTIONS   1.1 HOME FUNCTION (MENU Functions Home)   1.2 PRESET (MENU Functions Preset or Shortcut: PRST)   1.3 SCAN (MENU Functions Scan or Shortcut: SCAN)   1.4 TOUR (MENU Functions Tour or Shortcut: TOUR) ...
  • Page 13 Program and Operation 1. FUNCTION Pressing the MENU button on the keyboard controller, the following On-screen MAIN MENU will be shown on your monitor screen Main Menu Function Alarm Screen Camera Setup Password Communication Run Function Exit Locate the cursor on the FUNCTION item and then push the joystick to the right to enter FUNCTION menu.
  • Page 14 Program and Operation The Home function applied to the predefined functions such as Preset, Tour, Pattern, or Scan function after the keyboard controller has been idle for a programmed time. Follow the steps below to program the Home function: 1.Select the camera number by pressing No. and CAM 2.Press MENU to display the main menu on the monitor.
  • Page 15 Program and Operation There are 16 pages of preset programming menu. Each page can hold 8 presets. Locate the cursor on “PREV NEXT”, preset menu pages can be scrolled by pushing the Joystick to the Left or Right on the “PREV NEXT”.
  • Page 16 Program and Operation After aiming the camera (view direction and lens control) at specific position, push the focus button(Near, Far). The selected location No. field will be filled with “A A F”. Push the joystick to the right to select each Focus/ Iris /BLC mode using zoom handle. Move the cursor to the title field to edit/enter the title.
  • Page 17 Program and Operation 1.3 SCAN (MENU =>Function => Scan ; Short cut : SCAN) The Scan function supports up to 8 programmed section of angles at 8 programmable speeds Scan Menu 01/08 Scan 01 : AUTOSCAN01 Speed : 1~8 Start : 127.1, 027.0 zoom : 157.7, 080.7 zoom : CCW (PAN:000.0)
  • Page 18 Program and Operation 1.3 TOUR (MENU => Function => Tour ; Short cut : TOUR) There are 4 programmable Tours. Each Tour consists of up to 32 Preset positions, Patterns, Scans , or other Tours. Using second-level Tours, it can be expanded to over 56 functions in a single Tour. However tours second level Tours will be ignored when called by a Tours.
  • Page 19 Program and Operation Follow the steps below to program the Tours: Press MENU => Function => TOUR (Short Cut: TOUR) to display the main menu on the monitor. No. + SHFT+TOUR will open directly Tour No. Choose an empty location of function by pushing the Joystick up or down. Move the Joystick to left or right to enter the edit mode.
  • Page 20 Program and Operation 1.4 PATTERN (MENU => Function => Pattern ; Short cut : PATTERN) The Pattern function stores user’s control of the selected dome camera for up to 240 seconds. 4 patterns can be stored in 240 seconds of total recording space. Stored pattern is played back by pressing No.+ Pattern buttons subsequently Pattern Setup TILTIE...
  • Page 21 Program and Operation 2. ALARM Main Menu Function Alarm Screen Camera Setup Password Communication Run Function Exit Locate the cursor on ALARM item in the main menu and push the joystick to the right for ALARM programming of the camera. Alarm Setup No Fun Out Hld Latch...
  • Page 22 Program and Operation Press Menu to display the main menu on the monitor. Select the Alarm option by pushing the Joystick up or down and push to right to enter the detail menu. Select the alarm input number by pushing the Joystick up or down and select the column you wish to setup.
  • Page 23 Program and Operation 3.1 PRIVACY ZONE (MENU => Screen => Privacy Zone) Locate the cursor on the PRIVACY ZONE item and then push the joystick to the right to enter the menu. Screen Setup Privacy Zone North Direction Zone Title Camera Title OSD Display Exit...
  • Page 24 Program and Operation To adjust the “marked” (privacy) area, press zoom button or twist the Joystick to enter control mode and then use the Joystick (direction and zoom) until you get desired view. Press the Focus button to exit from control mode, the right column will be set to ON. You can overwrite an existing zone.
  • Page 25 Program and Operation Press MENU => SCREEN => ZONE TITLE to display zone title menu on the monitor. Select the zone number by pushing the Joystick up or down. Select Start, End or number column to be set by pushing the handle to the right or left. The selected column will be highlighted.
  • Page 26 Program and Operation 3.5 OSD DISPLAY (MENU => Screen => OSD Display) OSD Display Function Title : ON Camera Title : ON Zone Title : ON North Direction : OFF Camera Position : ON Camera ID : ON Zoom Magnification : ON Save And Exit Move the joystick handle right.
  • Page 27 Program and Operation Camera Menu Focus Control WB Control AE Control BLC/WDR Setup Sharpness : 6 (1~15) Digital Zoom : OFF/2x/4x/MAX Night Shot Camera Default Save And Exit 4.1 FOCUS CONTROL (MENU => Camera => Focus Control) Focus Setup Mode : MANUAL AF Sensitivity : NORMAL Exit...
  • Page 28 Program and Operation 4.3 AE(Auto Exposure) CONTROL (MENU => Camera => AE Control) Depending on your NEXPTZ camera, you will see either the following screen or the next. AE Setup Mode : FULL AUTO Slow Shutter : x10 Iris : Auto Gain : Auto Bright...
  • Page 29 Program and Operation 4.6 DIGITAL ZOOM (MENU => Camera => Digital Zoom) Digital Zoom : OFF (Optical Zoom only) / 2x / 4x / MAX (32x) Camera Menu Focus Control WB Control AE Control BLC/WDR Setup Sharpness Digital Zoom : OFF Night Shot Camera Default Save And Exit...
  • Page 30 Program and Operation 5. SETUP Main Menu Function Alarm Screen Camera Setup Password Communication Run Function Exit Locate the cursor on Setup item in the main menu and push the joystick to the right for Setup programming of the camera. Setup Menu Installation : NORMAL...
  • Page 31 Program and Operation 5.3 PANNING RANGE (MENU => Setup => Panning Range) Panning Range RIGHT LIMIT : ---.- LEFT LIMIT : ---.- ENABLE : OFF SWAP RIGHT/LEFT Save And Exit When NEXPTZ Camera in installed near a wall or on a corner, panning range(angle) can be limited with this function by user.
  • Page 32 Program and Operation 5.6 ERASE DATA (MENU => Setup => Erase Data) Erase Programmed DATA Are you sure?(Yes/No) YES : ENTER KEY or MENU KEY NO : ESC KEY Erase programmed data in the EEPROM of the selected NEXPTZ camera. Press MENU or ENTER button to erase data, ESC key to exit without erasing.
  • Page 33: Run Function

    Program and Operation 7. COMMUNICATION Communication Setup EX PTZ ID : 0001 Baudrate : 9600 Protocol : AUTO Save And Exit Move the joystick handle right. You can select EXPTZ ID to select the joystick up or down. Move the joystick handle right. You can select BARDRATE (2400/ 4800/ 9600/ 19200/ 38400) to select the joystick up or down.
  • Page 34: Specifications

    Specifications General Mechanical & Electrical Models NEXPTZ364NA NEXPTZ364PA Spec Signal System NTSC Ex. Class Ex d IIC T6 Certifications IECEx, ATEX, CE, FCC, KC Front window Fully tempered plate glass Material SUS 316 Protection Degree IP 67 Pan / Tilt Angle: 360° Continuous rotation Pan &...
  • Page 35 Specifications Camera Optical Models NEXPTZ364NA NEXPTZ364PA Spec Image Sensor 1/4" SONY Super HAD II (Double Scan) CCD Total pixels 1028(H) X 508(V) 1028(H) X 596(V) Scanning System 2:1 Interlace Scanning Frequency 15.734kHz(H),59.94Hz(V) 15.625kHz(H),50Hz(V) Sync. System Internal Resolution Max 700 TV lines in color @ HR 7 mode (750TV lines in B/W @ 7 mode) Min.
  • Page 36: Optional Accessories

    These are purchasing parts. MODEL NAME 1. NEXPTZ-PD: Pedestal mount bracket designed to mount NEXPTZ Series directly to a horizontal surface in either an upright or inverted position. 2. NEXPTZ-WL: Wall mount bracket designed to mount the NEXPTZ Series Camera directly to a load-bearing vertical surface.
  • Page 37 Dimensions Unit (mm) - 37 -...
  • Page 38 Optional Accessories Unit (mm) EXPTZ-PD EXPTZ-WL Unit (mm) - 38 -...
  • Page 39 Optional Accessories EXPTZ-CN Unit (mm) EXPTZ-PL Unit (mm) - 39 -...
  • Page 40: Remote Controller

    Remote Controller 1. POWER Power on/off. 2. NUMBERS Numeric keypads (0~9), 3. Camera Address (ID) Change camera ID. Number + CAM 4. WRITE PRESET(1~99) Saves camera picture’s condition. Number + SAVE 5. PRESET(1~99) Recall preset. Number + PRESET 6. HOME Immediately calls Home function.
  • Page 41 Honeywell Security Group. Honeywell Co., Ltd. Address : 5F, Sangam IT Tower, B4 - 4block, 1590 Sangam-dong Mapo-gu, Seoul 121-835, Republic of Korea TEL : +82 2 799 6114 / 6395 Printed in Korea FAX : +82 2 792 9011/ 799 6188...