Streamer LTO-3 half height 400GB/800GB SCSI Ultra320

Using the streamer

The control interface consists of the control button, the LED indicators and the mechanism of
inserting or ejecting a cartridge.
1 = LED-indicator "Clean"
2 = LED-indicator "Tape"
When a cartridge is removed, the cartridge door may remain open. In this case, make sure
!
that the cartridge door is closed again. Otherwise the streamer may be damaged.

Control button/function key

The control button/function key (5) can be used for three different functions:
to eject the cartridge in normal operation
to eject the cartridge in emergency operation (emergency removal)
Emergency reset of the streamer

Ejecting cartridge in normal operation

Press the control button/function key (5) briefly (about 1 second)
The cartridge is ejected (see section "Unloading a cartridge").
!
Ensure that all system operations are completed. Otherwise a data loss can be the result.
12 - English
3 = LED-indicator " Drive "
4 = LED-indicator " Ready "
5
3 4
1 2
5 = Control button/function key
6 = Ventilation slits