describes the chassis LEDs for the Cisco Nexus Fabric Extenders.
LEDs for the Cisco Nexus Fabric Extenders
LED
ID
Status
Status
Status
Description
On
Identifies the chassis receiving the beacon signal.
(blue)
Solid on
All diagnostics pass. The module is operational.
(green)
Blinking
The module is cold booting, or is operational but
(green)
the network interface ports are not connected to a
parent switch.
Off
The module is not receiving power.
On
The module is booting or running diagnostics.
(amber)
An overtemperature condition has occurred. The
temperature threshold has been exceeded by a
small value during environmental monitoring.
Blinking
An overtemperature condition has occurred. The
(amber)
temperature threshold has been exceeded by a
large value during environmental monitoring.
If the module fails during initial reset, the LED
continues to blink and the module does not come
online.
The module has a runtime failure and is brought
offline.
Solid on
All diagnostics pass. The module is operational.
(green)
Off
The module is not receiving power.
Solid on
The module is booting or running diagnostics.
(amber)
Blinking
If the module fails during initial reset, the LED
(amber)
continues to blink and the module does not come
online.
The module has a runtime failure and is brought
offline.