78 | Performance Series HQA Digital Video Recorder Remote User Guide
4.

Configuring for Abnormalities

Click Abnormality in the Event configuration interface to open the Abnormality configuration
interface.
www.honeywell.com/security
Table 3-16
Configuration
PTZ Activation
Snapshot
Voice Prompts
File Name
Show Message
Send Email
Buzzer
Message
Log
Click Save to save your settings.
Face Detection Configurations
Description
When PTZ activation is configured, the system can activate
PTZ operation when an alarm is detected.
1. Click Setup to open the PTZ Activation configuration
interface.
2. Select a preset, tour, or pattern from the drop-down menu.
3. Click Save.
Click to enable the Snapshot function. Channel snapshots
are taken according to the schedule you configure. Alarm
snapshots are taken when an alarm occurs.
Select to enable audio broadcast/voice prompts in response to
the event you selected in the drop-down list of event types.
Select a file for the voice prompt.
Click to enable a pop-up message on your local host PC
screen to let you know an alarm has occurred.
The system can send an email when an alarm is detected.
When you have enabled the Snapshot function, the system
can also send an image attached to the email. Go to Main
Menu
Setting
Network
settings. See
Configuring Email on page
Click to enable the Buzzer function. When an alarm occurs,
the buzzer beeps.
Enable to send a message to the device which supported the
3G/4G module when the event triggers.
Click to enable the DVR to record a local alarm log.
Email to configure the email
53.