6
FUNCTIONS
POINT
POINT
1. When setting a word device with a different value format, a device is regarded
as the same device.
[Example]
When a word device is set in the following order, "D100 (16 bit integer)", and
then "D100 (Real number (single precision))", "D100 (Real number (single
precision))" is registered.
2. When setting a device with a different modification method (such as a bit-
specified word device, digit-specified bit device or index-modified device), a
device is regarded as a different device.
[Example]
When a word device is set in the following order, "D100.F", and then "D100Z0
(Real number (single precision)), both devices are registered.
2) Step specification for executional conditioned device test registration
Any step number (0 to step number for the END instruction) in a sequence
program can be specified.
Be sure to specify the start step of each instruction.
3) Execution timing specification
Timing of changing a device value can be specified. A device value can be
changed either before or after an instruction of the specified step is executed.
Figure 6.43 shows the module operation based on the execution timing.
<Program example>
Ladder mode
Executional conditioned device test which
sets "20" in D0 in this step is registered.
<Operation>
Execution timing
Before executing
Processing
an instruction
of step 101
Value in D0
After executing
Processing
an instruction of
step 101
Value in D0
Figure 6.43 CPU module operation based on execution timing
CPU module operation
LD M0
Changes the value in D0 to "20".
10
LD M0
+ K100 D0
10
6.11 Monitor Function
6.11.4 Executional conditioned device test
List mode
+ K100 D0
20
120
Changes the value in D0 to "20".
110
20
6