Cisco MDS 9000 series Configuration Manual page 183

Nx-os ip services multilayer switches
Hide thumbs Also See for MDS 9000 series:
Table of Contents

Advertisement

Chapter 5
Configuring IP Services
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Figure 5-4
Note
To configure the management interface displayed in
address on the Ethernet network.
The following procedure configures an overlay VSAN in one switch. This procedure must be repeated
for each switch in the fabric.
To configure an overlay VSAN in one switch (using the example in
Command
Step 1
switch# config t
Step 2
switch(config)# vsan database
switch-config-vsan-db#
Step 3
switch--config-vsan-db# vsan 10 name MGMT_VSAN
Step 4
switch--config-vsan-db# exit
switch(config)#
Step 5
switch(config)# interface vsan 10
switch(config-if)#
Step 6
switch(config-if)# ip address 10.10.10.0
netmask 255.255.255.0
OL-19525-01,Cisco MDS NX-OS Release 4.2(1)
Overlay VSAN Configuration Example
Int vsan10 - 10.10.10.88
VSAN HR
Int vsan10 - 10.10.10.124
IP default gateway
10.10.10.34
VSAN 10
Int vsan10 - 10.10.10.35
Int vsan10 - 10.10.10.34
VSAN ENG
172.23.84.74
mgmt 0
172.23.84.86
NMS
IP cloud
ip route 10.10.10.0 255.255.255.0 172.23.93.74
Physical Fibre
Channel Fabric
Figure
5-4, set the default gateway to an IPv4
Purpose
Enters configuration mode.
Configures the VSAN database.
Defines the VSAN in the VSAN database on
all of the switches in the Fibre Channel fabric.
Exits the VSAN database mode.
Creates a VSAN interface (VSAN 10).
Assigns an IPv4 address and subnet mask for
this switch.
Cisco MDS 9000 Family NX-OS IP Services Configuration Guide
Overlay VSANs
Figure
5-4), follow these steps:
5-13