3.2.4 Touch panel

[
Function]
-Input system for display screen operation.
[Note at the replacement]
- Be sure to turn off the power at replacement.
- After replacement, insert the connectors to right places.
Caution when inserting or extracting touch panel connection cable
!
When inserting the touch panel connection
cable into the connector of the EZJ128
board, hold both sides of the reinforced
connecting portion as shown in the drawing,
and insert it so as not to fold the cable.
[Touch panel external view]
[Replacement procedure of touch panel]
[RX2-S, B]
(1) Refer to 3.2.4 LCD replacement procedure and remove the LCD.
(2) Remove the touch panel and install a new touch panel by performing opposite
procedure.
! Caution when replacing the touch panel
Wear the gloves when replacing the touch panel.
Handling with bare hands leaves fingerprints on the surface of the glass.
Wipe off the dust on the glass before replacement.
[RX2-S, B]
Maintenance door
3-11
Connection cable
Touch panel