Honeywell F100 Product Data

Honeywell F100 Product Data

Media air cleaner
Hide thumbs Also See for F100:

Advertisement

Available languages

Available languages

APPLICATION
The F100 Media Air Cleaner captures a significant amount of
the air-borne particles from the air circulated through the unit.

SPECIFICATIONS

IMPORTANT
The specifications in this publication do not include
normal manufacturing tolerances; therefore, an
individual unit may not exactly match the listed
specifications. This product is tested and calibrated
under closely controlled conditions, and some minor
differences in performance can be expected if those
conditions are changed.
Models:
F100F Media Air Cleaner includes cabinet, access door and
pleated media filter. Some units include a W8600A
AirWatch™ Indicator. F100B Media Air Cleaner includes
cabinet and access door.
Application:
Use with gas, oil, and electric forced warm air furnaces and
with compressor cooling. Can be used with heat pumps if
filter is changed regularly to prevent excessive pressure drop.
Not recommended for applications where pressure drop may
be critical.
® U.S. Registered Trademark
Copyright © 2003 Honeywell International Inc. • All Rights Reserved
Media Air Cleaner
FEATURES
• High efficiency media filter (included with some
models) captures particles as small as 0.3 micron.
• FC100A Efficiency and arrestance ratings based on
the American Society of Heating, Refrigerating and Air
Conditioning- Engineers Standard 52.2-1999.
• Applicable to all gas, oil, and electric forced warm air
furnaces and to compressor cooling up to 5 tons.
• Mounts in the return air duct.
• Cabinet can support weight of residential furnace and
evaporator coil.
• Requires no electrical connections.
• Mounts in any position.
• Requires no maintenance except periodic media filter
replacement.
• Quick and easy media filter replacement.
• Later upgrade to higher performing media or
electronic air cleaner is easy. (Note that 25 x 20 in. and
25 x 22 in. models cannot be upgraded to an electronic
air cleaner.)
FC100A Efficiency:
Efficiency Ratings: Based on American Society of Heating,
Refrigerating and Air-Conditioning Engineers Standard
52.2-1999.
Initial Efficiency: 15 percent (0.3 micron particles).
Minimum Efficiency Reporting Valve (MERV): 8 at 492 fpm.
Filter Media:
Pleated for greater media capacity.
Capacity And Pressure Drop:
See Fig 2.
Initial Pressure Drop: 0.177 in. wc at 492 fpm.
Temperature Rating:
-40° to +140°F (-40° to +60°C).
Dimensions:
See Fig. 1.
F100
PRODUCT DATA
68-0239EF-3

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell F100

  • Page 1: Specifications

    APPLICATION • Quick and easy media filter replacement. The F100 Media Air Cleaner captures a significant amount of • Later upgrade to higher performing media or the air-borne particles from the air circulated through the unit. electronic air cleaner is easy. (Note that 25 x 20 in. and 25 x 22 in.
  • Page 2: Ordering Information

    Upgrade Path: Mounts in any position in the return air duct, usually next to The F100 uses the same cabinet as the F50 Electronic Air the furnace blower compartment. Cabinet is sturdy enough to Cleaner. Upgrade may require installing the cell key, support weight of a residential furnace and evaporator coil.
  • Page 3: Applications With Air Conditioning

    F100 MEDIA AIR CLEANER Replacement Media: Applications With Air Conditioning For optimum system performance, replace the filter every six months (before heating season and before cooling season). Mount the media air cleaner upstream of the evaporator coil Adjust the schedule to you needs, but replace the filter at in a cooling system.
  • Page 4 F100 MEDIA AIR CLEANER M941A Fig. 5. Highboy furnace, with closet installation. Media air cleaner is mounted vertically on furnace between furnace and louvered return air opening in closet door. M943A Fig. 7. Counterflow furnace, with media air cleaner mounted horizontally in return duct or plenum just above furnace.
  • Page 5: Determining Sheetmetal Requirements

    F100 MEDIA AIR CLEANER Offsets If the duct connection to the furnace in a side installation allows less than 7 in. (178 mm) for mounting media air cleaner cabinet, attach an offset to the elbow. See Fig. 13. DUCT SIZE CHANGED GRADUALLY TO PREVENT TURBULENCE.
  • Page 6: Installation And Checkout

    F100 MEDIA AIR CLEANER INSTALLATION AND CHECKOUT Fasten Cabinet To Ductwork Fasten side of cabinet to the ductwork using sheet-metal When Installing this Product… screws, rivets, or slip joints, as appropriate. 1. Read these instructions carefully. Failure to follow them...
  • Page 7: Maintenance

    F100 MEDIA AIR CLEANER Install two AAA alkaline batteries (provided) in the harness on Maintenance the back of the device. Observe that the device performs a self-test, beeping and flashing the LC display individually for The W8600A beeps every fifteen minutes when an LCD is each device (air cleaner, UV air treatment system, humidifier) flashing.
  • Page 8 M18621A Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 429 Printed in U.S.A. on recycled paper containing at least 10% 68-0239EF–3 G.H. Rev. 7-03...
  • Page 9: Caractéristiques

    • N’exige aucun entretien à l’exception du remplacement périodique du filtre à fibres. Le filtre à air à élément filtrant à fibres F100 retient une importante • Remplacement simple et rapide du filtre à fibres. quantité de particules contenues dans l’air qui le traverse.
  • Page 10: Pour Commander

    2. Ou visiter notre site Web à www.honeywell.com/yourhome/ Au Canada : Honeywell Limited-Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9 Points de vente et de service dans toutes les grandes villes du monde. Usines en Allemagne, en Australie, au Canada, en Espagne, aux États-Unis, en Finlande, en France, au Japon, au Mexique, aux Pays-Bas, au Royaume-Uni et à...
  • Page 11: Planification De L'installation

    FILTRE À AIR À ÉLÉMENT FILTRANT À FIBRES F100 Médium filtrant de rechange : Applications – appareil de refroidissement Pour assurer au système un fonctionnement optimal, Le filtre à air devrait être installé en amont du serpentin de l’évaporateur. Le filtre à air aidera à garder le serpentin propre remplacer le filtre tous les six mois (avant la saison de chauffage et avant la saison de refroidissement).
  • Page 12 FILTRE À AIR À ÉLÉMENT FILTRANT À FIBRES F100 M941A Fig. 5. Appareil de chauffage à caissons superposés, dans une armoire. Filtre à air installé sur le côté à la verticale sur l’appareil de chauffage, entre l’appareil de chauffage et la grille de reprise d’air placée dans l’ouverture de la porte de l’armoire.
  • Page 13 FILTRE À AIR À ÉLÉMENT FILTRANT À FIBRES F100 MODIFICATION GRADUELLE DE LA TAILLE DE LA GAINE D’AIR EN VUE DE RÉDUIRE LA TURBULENCE. EXPANSION DE 20 DEGRÉS DE CHAQUE CÔTÉ, PAR RACCORD (100 mm par 300 mm linéaires) (4 po par pied linéaire).
  • Page 14: Installation

    FILTRE À AIR À ÉLÉMENT FILTRANT À FIBRES F100 INSTALLATION Installer les déflecteurs Installer les déflecteurs pour assurer une distribution uniforme AVANT D’INSTALLER CE PRODUIT... de l’air sur toute la surface amont du médium filtrant. Il faut les installer à l’intérieur du coude à 90 degrés, montés directement sur le boîtier du filtre à...
  • Page 15 FILTRE À AIR À ÉLÉMENT FILTRANT À FIBRES F100 Suivre les réglages qui figurent au dos du W8600A pour régler remettre la minuterie à zéro, il faut ensuite appuyer sur le les microrupteurs pour 3, 6, 9, ou 12 mois. Utiliser les réglages bouton de réarmement et le maintenir enfoncée pendant cinq...
  • Page 16 Économisez jusqu’à 30 % du coût annuel de l’énergie grâce à ce thermostat d’installation facile* * selon l’emplacement géographique et l’utilisation Régulation résidentielle et commerciale Honeywell International Inc. Honeywell Limited – Honeywell Limitée 1985 Douglas Drive North 35, Dynamic Drive Golden Valley, MN 55422 Scarborough (Ontario) M1V 4Z9 Imprimé...

Table of Contents