APPENDIX B
F530
ENUMERATION: FRONT PANEL INTERFACE KEYPRESS
value
keypress
value
keypress
0
None
15
1
Menu
16
2
Message Up
17
Message
3
7
18
~
4
8
19
Decimal
5
9
20
6
Help
21
Value Up
7
Message Left
22
Value Down
8
4
23
9
5
24
10
6
25
11
Escape
26
12
Message
31
User PB 1
Right
13
1
32
User PB 2
14
2
F531
ENUMERATION: LANGUAGE
0 = English, 1 = French, 2 = Chinese, 3 = Russian, 4 = Turkish
F600
UR_UINT16: FLEXANALOG PARAMETER
Corresponds to the Modbus address of the value used when this
parameter is selected. Only certain values may be used as Flex-
Analogs (basically all metering quantities used in protection).
F605
ENUMERATION: REMOTE DOUBLE-POINT STATUS INPUT
STATUS
Enumeration
Remote DPS input status
0
Intermediate
1
Off
2
On
3
Bad
F606
ENUMERATION: REMOTE DOUBLE-POINT STATUS INPUT
Enumeration
Remote double-point status input
0
None
1
Remote input 1
2
Remote input 2
3
Remote input 3
64
Remote input 64
GE Multilin
value
keypress
3
33
User PB 3
Enter
34
User PB 4
35
User PB 5
Down
0
36
User PB 6
~
37
User PB 7
+/–
38
User PB 8
39
User PB 9
40
User PB 10
Reset
41
User PB 11
User 1
42
User PB 12
User 2
44
User 4
User 3
45
User 5
46
User 6
47
User 7
C30 Controller System
F611
ENUMERATION: GOOSE RETRANSMISSION SCHEME
Enumeration
Configurable GOOSE retransmission scheme
0
Heartbeat
1
Aggressive
2
Medium
3
Relaxed
F612
UR_UINT16: FLEXINTEGER PARAMETER
This 16-bit value corresponds to the Modbus address of the
selected FlexInteger parameter. Only certain values may be used
as FlexIntegers.
F615
ENUMERATION: IEC 61850 REPORT DATASET ITEMS
Enumeration
IEC 61850 report dataset items
0
None
1
PDIF1.ST.Str.general
2
PDIF1.ST.Op.general
3
PDIF2.ST.Str.general
4
PDIF2.ST.Op.general
5
PDIF3.ST.Str.general
6
PDIF3.ST.Op.general
7
PDIF4.ST.Str.general
8
PDIF4.ST.Op.general
9
PDIS1.ST.Str.general
10
PDIS1.ST.Op.general
11
PDIS2.ST.Str.general
12
PDIS2.ST.Op.general
13
PDIS3.ST.Str.general
14
PDIS3.ST.Op.general
15
PDIS4.ST.Str.general
16
PDIS4.ST.Op.general
17
PDIS5.ST.Str.general
18
PDIS5.ST.Op.general
19
PDIS6.ST.Str.general
20
PDIS6.ST.Op.general
21
PDIS7.ST.Str.general
22
PDIS7.ST.Op.general
23
PDIS8.ST.Str.general
24
PDIS8.ST.Op.general
25
PDIS9.ST.Str.general
26
PDIS9.ST.Op.general
27
PDIS10.ST.Str.general
28
PDIS10.ST.Op.general
29
PIOC1.ST.Str.general
30
PIOC1.ST.Op.general
31
PIOC2.ST.Str.general
32
PIOC2.ST.Op.general
33
PIOC3.ST.Str.general
B.4 MEMORY MAPPING