GE RPV311 Technical Manual page 261

Distributed multifunction fault recorder
Table of Contents

Advertisement

Chapter 17 – Technical Specifications
RPV311-TM-EN-7
IEC 61000-4-
17:1999
IEC 61000-4-
18:2006
Gradual Startup
CISPR11:2009
CISPR22:2008
BS EN 60255-21-3:
1995
Seismic
Number of repetition: 3
Test level: 15 % of rated d.c. value
Test frequency: 120Hz, sinusoidal waveform.
Voltage oscillation frequency: 1MHz
Differential mode: 1kV peak voltage;
Common mode 2,5kV peak voltage
Shut-down ramp: 60s
Power off: 5m
Start-up ramp: 60s
Radiated emission
Limits:
30 to 230MHz - 50dB(μV/m) quasi peak at 3m
230 to 1000MHz - 57dB(μV/m) quasi peak at 3m
Radiated emission
Limits:
1 to 3GHz - 56dB(μV/m) average; 76dB(μV/m)
peak at 3m
3 to 6GHz - 60dB(μV/m) average; 80dB(μV/m)
peak at 3m
The test frequency is defined based on the
maximum internal frequency of equipment.
Conducted emission
Limits:
0.15 to 0.50MHZ - 79dB(μV) quasi peak; 66dB(μV)
average
0.5 to 30MHz - 73dB(μV) quasi peak; 60dB(μV)
average
Class 2
Horizontal Axes:
Frequency Range: 1Hz – 35Hz
RPV311
261