Troubleshooting

Fault
The unit is not working

Technical Specifications

Model
Voltage
L310
S047
S007
S377
230V 50Hz
L371
S378
S077
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The thermal cut out switch has
tripped
The thermostat has not been
set correctly
The heating element has failed Call BUFFALO agent or qualified
Power
Current
1500W
6.6A
3
Check the unit is plugged in correctly
and switched on
Call BUFFALO agent or qualified
technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified
technician
Call BUFFALO agent or qualified
technician
Set the thermostat to a higher
temperature
technician
Dimensions
Weight
h x w x d mm
10.8kg
270 x 340 x 615
10.8kg
275 x 340 x 615
10.8kg
275 x 340 x 615
10.8kg
275 x 340 x 615
10.8kg
270 x 340 x 615
10.8kg
270 x 340 x 615
11.25kg
324 x 340 x 565