Error Log Display (Elog) - Panasonic KX-TVS50 Installation Manual

Voice processing system
Hide thumbs Also See for KX-TVS50:
Table of Contents

Advertisement

printer or data terminal must be connected to the VPS at the RS-232C port for the reports to be
printed or displayed.
1.
Type PSET, then Press RETURN.
$ PSET
Report Print Out Service [ Disable ]
1 : Enable 2: Disable :=
2.
Type [1] to enable this function or Type [2] to disable it.
Enter The Print Out Time (HH:MM, AM/PM) :=
3.
Type the time to print the reports.
Note
The reports will be displayed only if the system is in the mode where the ">" prompt
is displayed.

7.2.6 Error Log Display (ELOG)

This command is used when diagnosing VPS problems. When selected, this command will
display an error log.
COM. Communication error between CPU and DSP
DATA Process error of voice data
MEM. Memory error
PRG. Program error in CPU card
R/W Read/Write error of Flash Memory
Type ELOG, then Press RETURN.
$ ELOG
Note
The errors that can be identified by the system are displayed and explained in the following
tables.
SYSTEM MAINTENANCE AND TROUBLESHOOTING
DEVICE
ERROR
1. CPU
MEM-GET
2. CLOCK
3. FLASH
DATA R/W (xx:yyyy)
MEMORY
4. DSP*
SCAN
5. DSP*
FIFO
6. CPU
APPLICATION (x)
* = Port number (1-2)
7.2 UTILITY COMMANDS
TIME
JUL-14 14:00 PM
JUL-14 14:00 PM
JUL-14 14:00 PM
JUL-14 14:00 PM
JUL-14 14:00 PM
JUL-14 14:00 PM
137