Internal Labels

Database Configuration Label and HEX-Dump Mode

MP Nova Mark II User Guide
The Database Configuration Label provides information including the printer
firmware version, memory allocations, enabled options and label-counter data.
1 Load the media [10.16 cm (4 in.) wide] and ribbon (if printing with a thermal
transfer media).
2 Turn the printer on.
3 When the LED is solid red, press and hold the control button until the LED
turns solid green (up to 60 seconds) and then release. The Database
Configuration Label will then print.
Note: Printed label may not match the label shown above.
4 After the printer finishes printing the Database Configuration Labels, the
printer is in HEX-Dump Mode. Cycle printer power to exit the HEX-Dump
Mode.